{"id":7732,"date":"2026-03-10T17:22:40","date_gmt":"2026-03-10T09:22:40","guid":{"rendered":"https:\/\/meettfit.com\/?p=7732"},"modified":"2026-04-08T16:30:18","modified_gmt":"2026-04-08T08:30:18","slug":"what-fire-rating-should-gym-flooring-meet","status":"publish","type":"post","link":"https:\/\/meettfit.com\/nl\/akoestische-onderlaag\/aan-welke-brandklasse-moeten-sportschoolvloeren-voldoen\/","title":{"rendered":"Aan welke brandclassificatie moet sportschoolvloer voldoen"},"content":{"rendered":"<p><strong>Commerci\u00eble sportschoolvloeren moeten voldoen aan een brandklasse I, zoals gedefinieerd door ASTM E648 met een kritische stralingsflux van $ geq 0,45$ watt\/cm\u00b2. Daarnaast moet de Smoke Developed Index (SDI) onder 450 liggen volgens ASTM E662 om te voldoen aan de International Building Code (IBC) en de NFPA 101 Life Safety Code.<\/strong><\/p>\n<blockquote>\n<h3>Snel antwoord: Vereisten brandclassificatie sportschool<\/h3>\n<ul>\n<li><strong>Commerci\u00eble sportscholen:<\/strong> Klasse I (ASTM E648 $\\geq 0.45$ W\/cm\u00b2) + SDI &lt; 450.<\/li>\n<li><strong>Boetiek Studio's:<\/strong> Klasse I aanbevolen (Klasse II 1,22$ W\/cm\u00b2 minimaal in sommige rechtsgebieden).<\/li>\n<li><strong>Sportscholen thuis:<\/strong> ASTM D2859 (Piltest) is de standaard baseline.<\/li>\n<li><strong>Uitgangen:<\/strong> Klasse I is verplicht voor gangen en uitgangen.<\/li>\n<\/ul>\n<\/blockquote>\n<p>Als aannemer die duizenden vierkante meters rubber vloerbedekking heeft ge\u00efnstalleerd, heb ik gezien dat veel eigenaren van sportscholen de voorkeur geven aan esthetiek of kosten boven naleving van de bouwvoorschriften. Het kiezen van de verkeerde vloerbedekking is een enorme aansprakelijkheid. Brandclassificaties zijn niet slechts \"suggesties\"; het zijn wettelijke vereisten die worden opgelegd door de IBC en lokale brandweerkorpsen. In een ruimte met zware apparatuur en een hoge bezettingsgraad is de vloer het grootste oppervlak. Als dat oppervlak werkt als een versneller, loop je het risico dat je inspectie al mislukt voordat je open bent. Ik vertel mijn klanten altijd dat een mooie vloer waardeloos is als de brandweer je opdraagt hem eruit te slopen.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-5.jpg&quot;\" alt=\"ASTM E648 brandwerendheidstest voor rubberen sportschoolvloeren\" \/><\/p>\n<p>Veiligheid en esthetiek moeten hand in hand gaan met de technische benchmarks die worden gebruikt om te evalueren <a href=\"https:\/\/meettfit.com\/nl\/commerciele-vloeren-weten\/welke-meetcriteria-definieren-hoogwaardige-sportvloeren\/\">hoogwaardige sportvloeren<\/a> in a successful fitness environment. Let us look at why these ratings are the foundation of your gym&#8217;s infrastructure.<\/p>\n<h2>Waarom zijn bouwvoorschriften zoals IBC en NFPA belangrijk voor uw sportschool?<\/h2>\n<p><strong>De International Building Code (IBC) en de NFPA 101 schrijven voor dat de vloerafwerking in gangen met uitgangen naar sportzalen moet voldoen aan klasse I-normen om een veilige evacuatie tijdens een brand te garanderen.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Code Autoriteit<\/th>\n<th style=\"text-align: left;\">Relevante norm<\/th>\n<th style=\"text-align: left;\">Vereiste voor sportscholen<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>IBC (hoofdstuk 8)<\/strong><\/td>\n<td style=\"text-align: left;\">ASTM E648<\/td>\n<td style=\"text-align: left;\">Klasse I voor gangen met uitgangen<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>NFPA 101<\/strong><\/td>\n<td style=\"text-align: left;\">Code voor levensveiligheid<\/td>\n<td style=\"text-align: left;\">Verplicht Klasse I of II op basis van bezetting<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Lokale brandvoorschriften<\/strong><\/td>\n<td style=\"text-align: left;\">ASTM E662<\/td>\n<td style=\"text-align: left;\">Rookontwikkelingsindex (SDI) &lt; 450<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>In mijn jaren op bouwplaatsen heb ik gemerkt dat het dilemma \"veiligheid versus esthetiek\" vaak voortkomt uit een gebrek aan kennis van de voorschriften. De meeste commerci\u00eble sportscholen vallen onder \"Assembly\" of \"Business\" bezetting. Volgens de IBC moet een vloer van klasse I zijn als deze in een vluchtroute ligt. Ik heb ooit een project geleid waarbij de klant gerecyclede matten zonder classificatie kocht voor hun fitnessruimte. De brandweer blokkeerde het gebruikscertificaat omdat de matten rechtstreeks naar de nooduitgang leidden. We moesten 500 vierkante meter rubber verscheuren. Daarom sta ik erop dat de <strong>Kritische stralingsflux<\/strong> waarden en de <strong>Rookontwikkelingsindex (SDI)<\/strong>. Als de SDI hoger is dan 450, zal de dikke rook inzittenden verblinden die proberen uitgangen te vinden.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-4.jpg&quot;\" alt=\"Brandveiligheidsinspectie voor commerci\u00eble sportscholen\" \/><\/p>\n<p>Het volgen van deze normen is de enige manier om je investering en de mensen in je gebouw te beschermen.<\/p>\n<h2>Wat is de \"alfabetische soep\" van brandclassificaties (ASTM E648 &amp; E662)?<\/h2>\n<p><strong>De gouden industriestandaard is ASTM E648, die meet hoeveel warmte-energie er nodig is om een vlam te verspreiden, terwijl ASTM E662 de giftige rookproductie beperkt.<\/strong><\/p>\n<h3>Technische prestatiecijfers uitsplitsen<\/h3>\n<p>Wanneer we naar laboratoriumrapporten kijken, richten we ons op twee belangrijke getallen. Het eerste getal is de kritische stralingsflux (ASTM E648). Een classificatie van klasse I betekent dat het materiaal minstens $0,45$ watt\/cm\u00b2 nodig heeft om een vlam in stand te houden. Klasse II vereist slechts $0,22$ watt\/cm\u00b2. Ten tweede is er de Smoke Developed Index (SDI) van de ASTM E662-test. Voor de meeste commerci\u00eble interieurafwerkingen moet de SDI onder 450 liggen. Als aannemer heb ik \"brandwerend\" rubber gezien dat de vlamtest doorstaat, maar de rooktest niet. Dit komt vaak voor bij laagwaardig gerecycled SBR-rubber met een hoog oliegehalte. Als het brandt, produceert het een \"zwarte muur\" van rook. Internationale projecten kunnen ook verwijzen naar EN 13501-1 (Euroklasse), maar voor projecten in de VS zal uw verzekeringsmaatschappij de ASTM-standaarden eisen.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Testnorm<\/th>\n<th style=\"text-align: left;\">Doel<\/th>\n<th style=\"text-align: left;\">Metrisch passeren (Klasse I)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>ASTM E648<\/strong><\/td>\n<td style=\"text-align: left;\">Vlamverspreiding<\/td>\n<td style=\"text-align: left;\">$\\geq 0,45$ W\/cm\u00b2<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>ASTM E662<\/strong><\/td>\n<td style=\"text-align: left;\">Rookdichtheid<\/td>\n<td style=\"text-align: left;\">$&lt; 450$ SDI<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>ASTM D2859<\/strong><\/td>\n<td style=\"text-align: left;\">Ontsteking<\/td>\n<td style=\"text-align: left;\">\"Pas\" (Dooft zichzelf uit)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-6.jpg&quot;\" alt=\"rubberen vloerbedekking brandklasse ASTM E648 labtest\" \/><\/p>\n<p>Veel mensen denken dat elke rubberen mat veilig is, maar zonder deze specifieke testresultaten neem je een enorme gok.<\/p>\n<h2>Is het materiaal van uw vloer van invloed op de brandprestaties?<\/h2>\n<p><strong>Hoogwaardige rubbervloeren gebruiken nieuw EPDM en gespecialiseerde brandvertragende additieven om te voldoen aan de klasse I normen, terwijl standaard gerecycled rubber deze bescherming vaak mist.<\/strong><\/p>\n<h3>Materiaalwetenschap en techniekoptimalisatie<\/h3>\n<p>Materialen vormen de basis van brandveiligheid. Standaard gerecycled SBR (bandenrubber) is van nature brandbaar vanwege de aardolieproducten die worden gebruikt bij de productie van banden. Om deze matten te laten voldoen aan klasse I, moeten we brandvertragers zoals aluminiumtrihydraat integreren tijdens het vulkanisatieproces. Dit additief geeft waterdamp af wanneer het wordt blootgesteld aan grote hitte, waardoor het materiaal afkoelt en de vlam vertraagt. Ik raad vaak nieuwe EPDM toplagen aan omdat deze stabieler zijn onder thermische stress. Een andere factor is de \"lijmfactor\". Ik heb een klasse I vloer zien mislukken omdat de installateur een goedkope, brandbare lijm op basis van oplosmiddelen gebruikte. De lijm ontbrandde onder de tegels en cre\u00eberde een \"schoorsteeneffect\" bij de naden. Daarom gebruik ik altijd lijmen met een hoog oplosmiddelgehalte en een laag VOS-gehalte die overeenkomen met de brandklasse van de vloer zelf.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Type materiaal<\/th>\n<th style=\"text-align: left;\">Brandprestaties<\/th>\n<th style=\"text-align: left;\">Beste gebruikscasus<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Behandeld SBR<\/strong><\/td>\n<td style=\"text-align: left;\">Goed (met additieven)<\/td>\n<td style=\"text-align: left;\">Algemene tilgebieden<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Maagdelijk EPDM<\/strong><\/td>\n<td style=\"text-align: left;\">Uitstekend<\/td>\n<td style=\"text-align: left;\">Veel verkeer, goed zichtbaar<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>In elkaar grijpende tegels<\/strong><\/td>\n<td style=\"text-align: left;\">Variabel (controleer de naden)<\/td>\n<td style=\"text-align: left;\">Sportscholen aan huis \/ Kleine studio's<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-3.jpg&quot;\" alt=\"brandwerende EPDM rubber vloerbedekking doorsnede\" \/><\/p>\n<p>Het gebruik van de juiste materialen lost ontwerpproblemen op voordat ze uitgroeien tot veiligheidsrisico's of inspectiefouten. Brandprestaties zijn slechts \u00e9\u00e9n onderdeel van de beslissing, dus eigenaren moeten ook bredere selectiecriteria bekijken bij het kiezen van de juiste materialen. <a href=\"https:\/\/meettfit.com\/nl\/akoestische-onderlaag\/wat-is-de-beste-vloer-voor-sportscholen\/\">beste vloer voor hun sportschool<\/a>.<\/p>\n<h2>Hoe kun je veelgemaakte fouten vermijden en beoordelingen verifi\u00ebren?<\/h2>\n<p><strong>Vraag altijd het volledige laboratoriumrapport van een derde partij en het veiligheidsinformatieblad (MSDS), zorg ervoor dat het \"Jaar van testen\" actueel is en overeenkomt met het product dat verkocht wordt.<\/strong><\/p>\n<h3>The Contractor&#8217;s Checklist for Verification<\/h3>\n<p>The biggest mistake is the &quot;Cheap Import Trap.&quot; I see gym owners buying uncertified rubber from mass marketplaces to save 30%. These products rarely have legitimate ASTM E648 certifications. When you request a report, check for the lab&#8217;s stamp. If the report is more than 5 years old, it may not reflect current manufacturing processes. Also, look at the Product ID. The name on the lab report must match the name on your invoice exactly. If there is a discrepancy, the fire marshal will likely reject it. Finally, check your insurance policy. Many commercial providers now require proof of Class I flooring to cover fire damage claims. If you cannot provide a valid report after a fire, your claim could be denied. <\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Document nodig<\/th>\n<th style=\"text-align: left;\">Belangrijkste Sectie<\/th>\n<th style=\"text-align: left;\">Waar moet je op letten?<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Labrapport<\/strong><\/td>\n<td style=\"text-align: left;\">Samenvatting test<\/td>\n<td style=\"text-align: left;\">Kritische stralingsflux $geq 0.45$<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>SDS<\/strong><\/td>\n<td style=\"text-align: left;\">Sectie 5<\/td>\n<td style=\"text-align: left;\">Blusmiddelen en ontvlambaarheid<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>COA<\/strong><\/td>\n<td style=\"text-align: left;\">Batchnummer<\/td>\n<td style=\"text-align: left;\">Verbinding met de specifieke productierun<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-1.jpg&quot;\" alt=\"aannemer die ASTM-certificaten voor rubbervloeren met brandclassificatie controleert\" \/><\/p>\n<h2>FAQ: Veelgestelde vragen over brandclassificaties voor sportscholen<\/h2>\n<h3>Is een rubberen sportschoolvloer brandwerend?<\/h3>\n<p>Standaardrubber is van nature niet brandwerend. Het moet speciaal worden ontwikkeld met vlamvertragende additieven om te voldoen aan bouwvoorschriften zoals ASTM E648.<\/p>\n<h3>Voldoen rubberen gymnastiekmatten aan ASTM E648?<\/h3>\n<p>Alleen matten van hoge kwaliteit worden getest met ASTM E648. De meeste \"budget\" matten slagen alleen voor de ASTM D2859 piltest, die onvoldoende is voor commerci\u00eble uitgangen.<\/p>\n<h3>Welke brandklasse is vereist voor commerci\u00eble sportscholen?<\/h3>\n<p>De meeste plaatselijke voorschriften vereisen een klasse I rating ($\\q 0.45$ W\/cm\u00b2) voor gangen en uitgangen, en minstens klasse II voor algemene vloeroppervlakken in sportzalen.<\/p>\n<h3>Kunnen gerecyclede rubbervloeren voldoen aan klasse I?<\/h3>\n<p>Ja, maar alleen als de fabrikant specifieke brandwerende chemicali\u00ebn gebruikt tijdens de productie. Vraag altijd om het labrapport ter bevestiging.<\/p>\n<h2>Conclusie<\/h2>\n<p>Brandveiligheid is een onmisbaar onderdeel van het ontwerp van een fitnessruimte. Klasse I (ASTM E648) is de veiligste norm.<\/p>\n<hr \/>\n<p><strong>Heeft u brandwerende rubberen gymvloeren nodig voor uw project?<\/strong><\/p>\n<p>Our Class I certified rubber flooring meets all ASTM E648 and ASTM E662 requirements and is rigorously tested by Intertek laboratories. Don&#8217;t risk your permit or your safety with unrated materials. <\/p>\n<p><strong>Neem vandaag nog contact met ons op voor volledige productspecificaties, laboratoriumrapporten en een professioneel advies voor uw bedrijf.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>Commercial gym flooring must meet a Class I Fire Rating, defined by ASTM E648 with a Critical Radiant Flux of $\\geq 0.45$ watts\/cm\u00b2. Additionally, the Smoke Developed Index (SDI) must typically be under 450 per ASTM E662 to comply with International Building Code (IBC) and NFPA 101 Life Safety Code. \u26a1 Quick Answer: Gym Fire&#8230;<\/p>","protected":false},"author":4,"featured_media":7741,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[25],"tags":[],"class_list":["post-7732","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-acoustic-underlay"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What Fire Rating Should Gym Flooring Meet - MF FLOOR<\/title>\n<meta name=\"description\" content=\"Discover the fire safety standards for rubber gym flooring, including ASTM E648, ASTM E662, and IBC building code requirements.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/meettfit.com\/nl\/akoestische-onderlaag\/aan-welke-brandklasse-moeten-sportschoolvloeren-voldoen\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Fire Rating Should Gym Flooring Meet - MF FLOOR\" \/>\n<meta property=\"og:description\" content=\"Discover the fire safety standards for rubber gym flooring, including ASTM E648, ASTM E662, and IBC building code requirements.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/meettfit.com\/nl\/akoestische-onderlaag\/aan-welke-brandklasse-moeten-sportschoolvloeren-voldoen\/\" \/>\n<meta property=\"og:site_name\" content=\"MF FLOOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-10T09:22:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-08T08:30:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"1659230944@qq.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschreven door\" \/>\n\t<meta name=\"twitter:data1\" content=\"1659230944@qq.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/\"},\"author\":{\"name\":\"1659230944@qq.com\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\"},\"headline\":\"What Fire Rating Should Gym Flooring Meet\",\"datePublished\":\"2026-03-10T09:22:40+00:00\",\"dateModified\":\"2026-04-08T08:30:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/\"},\"wordCount\":1349,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg\",\"articleSection\":[\"Soundproof Flooring Solutions\"],\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/\",\"url\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/\",\"name\":\"What Fire Rating Should Gym Flooring Meet - MF FLOOR\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg\",\"datePublished\":\"2026-03-10T09:22:40+00:00\",\"dateModified\":\"2026-04-08T08:30:18+00:00\",\"description\":\"Discover the fire safety standards for rubber gym flooring, including ASTM E648, ASTM E662, and IBC building code requirements.\",\"breadcrumb\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg\",\"width\":800,\"height\":600,\"caption\":\"Gym Flooring Fire Rating (2)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/meettfit.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Fire Rating Should Gym Flooring Meet\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/meettfit.com\/#website\",\"url\":\"https:\/\/meettfit.com\/\",\"name\":\"MF FLOOR\",\"description\":\"fitness and sports floor China factory\",\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"alternateName\":\"MF FLOOR\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/meettfit.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/meettfit.com\/#organization\",\"name\":\"MF FLOOR\",\"alternateName\":\"MF FLOOR\",\"url\":\"https:\/\/meettfit.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"width\":512,\"height\":512,\"caption\":\"MF FLOOR\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\",\"name\":\"1659230944@qq.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"caption\":\"1659230944@qq.com\"},\"url\":\"https:\/\/meettfit.com\/nl\/author\/1659230944qq-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What Fire Rating Should Gym Flooring Meet - MF FLOOR","description":"Discover the fire safety standards for rubber gym flooring, including ASTM E648, ASTM E662, and IBC building code requirements.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/meettfit.com\/nl\/akoestische-onderlaag\/aan-welke-brandklasse-moeten-sportschoolvloeren-voldoen\/","og_locale":"nl_NL","og_type":"article","og_title":"What Fire Rating Should Gym Flooring Meet - MF FLOOR","og_description":"Discover the fire safety standards for rubber gym flooring, including ASTM E648, ASTM E662, and IBC building code requirements.","og_url":"https:\/\/meettfit.com\/nl\/akoestische-onderlaag\/aan-welke-brandklasse-moeten-sportschoolvloeren-voldoen\/","og_site_name":"MF FLOOR","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100079773047357","article_published_time":"2026-03-10T09:22:40+00:00","article_modified_time":"2026-04-08T08:30:18+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg","type":"image\/jpeg"}],"author":"1659230944@qq.com","twitter_card":"summary_large_image","twitter_misc":{"Geschreven door":"1659230944@qq.com","Geschatte leestijd":"2 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#article","isPartOf":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/"},"author":{"name":"1659230944@qq.com","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef"},"headline":"What Fire Rating Should Gym Flooring Meet","datePublished":"2026-03-10T09:22:40+00:00","dateModified":"2026-04-08T08:30:18+00:00","mainEntityOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/"},"wordCount":1349,"commentCount":0,"publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg","articleSection":["Soundproof Flooring Solutions"],"inLanguage":"nl-NL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/","url":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/","name":"What Fire Rating Should Gym Flooring Meet - MF FLOOR","isPartOf":{"@id":"https:\/\/meettfit.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg","datePublished":"2026-03-10T09:22:40+00:00","dateModified":"2026-04-08T08:30:18+00:00","description":"Discover the fire safety standards for rubber gym flooring, including ASTM E648, ASTM E662, and IBC building code requirements.","breadcrumb":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#primaryimage","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/gym-flooring-fire-rating-2.jpg","width":800,"height":600,"caption":"Gym Flooring Fire Rating (2)"},{"@type":"BreadcrumbList","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-fire-rating-should-gym-flooring-meet\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/meettfit.com\/"},{"@type":"ListItem","position":2,"name":"What Fire Rating Should Gym Flooring Meet"}]},{"@type":"WebSite","@id":"https:\/\/meettfit.com\/#website","url":"https:\/\/meettfit.com\/","name":"MF FLOOR","description":"fitness and sports floor China factory","publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"alternateName":"MF FLOOR","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/meettfit.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/meettfit.com\/#organization","name":"MF FLOOR","alternateName":"MF FLOOR","url":"https:\/\/meettfit.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","width":512,"height":512,"caption":"MF FLOOR"},"image":{"@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100079773047357"]},{"@type":"Person","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef","name":"1659230944@qq.com","image":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/meettfit.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","caption":"1659230944@qq.com"},"url":"https:\/\/meettfit.com\/nl\/author\/1659230944qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/posts\/7732","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/comments?post=7732"}],"version-history":[{"count":1,"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/posts\/7732\/revisions"}],"predecessor-version":[{"id":7748,"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/posts\/7732\/revisions\/7748"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/media\/7741"}],"wp:attachment":[{"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/media?parent=7732"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/categories?post=7732"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meettfit.com\/nl\/wp-json\/wp\/v2\/tags?post=7732"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}