{"id":9538,"date":"2026-07-23T17:00:45","date_gmt":"2026-07-23T09:00:45","guid":{"rendered":"https:\/\/meettfit.com\/?p=9538"},"modified":"2026-07-23T10:56:14","modified_gmt":"2026-07-23T02:56:14","slug":"how-do-contractors-inspect-installed-pvc-sports-flooring","status":"publish","type":"post","link":"https:\/\/meettfit.com\/fr\/pvc-floor-blog\/comment-les-entrepreneurs-procedent-ils-a-linspection-des-revetements-de-sol-sportifs-en-pvc-deja-poses\/","title":{"rendered":"Comment les entrepreneurs proc\u00e8dent-ils \u00e0 l'inspection des rev\u00eatements de sol sportifs en PVC d\u00e9j\u00e0 pos\u00e9s ?"},"content":{"rendered":"<p><strong>Une inspection post-installation en bonne et due forme porte sur quatre \u00e9l\u00e9ments : la plan\u00e9it\u00e9 de la surface, l'int\u00e9grit\u00e9 des joints, l'adh\u00e9rence et la conformit\u00e9 aux normes (EN 14904 \/ ASTM F2772). Le fait de n\u00e9gliger cette \u00e9tape peut compromettre la s\u00e9curit\u00e9 des athl\u00e8tes, entra\u00eener l'annulation des garanties et provoquer une d\u00e9faillance pr\u00e9matur\u00e9e du rev\u00eatement de sol.<\/strong><\/p>\n<p>J'ai inspect\u00e9 des centaines de sols termin\u00e9s avant leur r\u00e9ception d\u00e9finitive, et je peux vous affirmer ceci : un sol qui semble impeccable vu depuis la porte peut tout de m\u00eame cacher des probl\u00e8mes. Des cloques sous la surface, un joint fragile pr\u00e8s d\u2019un mur, une irr\u00e9gularit\u00e9 du sous-plancher qui transpara\u00eet \u00e0 travers le PVC\u2026 Ces probl\u00e8mes n\u2019apparaissent pas toujours d\u00e8s le premier jour. Ils se manifestent six mois plus tard, apr\u00e8s un passage intense et quelques variations de temp\u00e9rature. C\u2019est pourquoi je consid\u00e8re l\u2019inspection comme un processus structur\u00e9, et non comme une simple visite rapide. Je la d\u00e9compose en plusieurs phases : pr\u00e9paration, contr\u00f4le visuel, v\u00e9rification de la liste de contr\u00f4le, examen des joints et des soudures, outils adapt\u00e9s, tests de performance physique, conformit\u00e9 aux normes, enregistrement des d\u00e9fauts et validation finale. Chaque phase permet de d\u00e9tecter un type de risque diff\u00e9rent, et en sauter une seule laisse une lacune qui se traduira plus tard par une r\u00e9clamation au titre de la garantie ou un risque pour la s\u00e9curit\u00e9.<\/p>\n<p>Avant de prendre votre liste de contr\u00f4le et de commencer \u00e0 faire le tour du terrain, il y a quelques pr\u00e9paratifs \u00e0 effectuer. Je vais commencer par vous expliquer ce qui se passe avant m\u00eame que l'inspection ne commence.<\/p>\n<h2>Que faut-il v\u00e9rifier avant le d\u00e9but de la visite de remise des cl\u00e9s ?<\/h2>\n<p><strong>Attendez 24 \u00e0 72 heures que l'adh\u00e9sif durcisse, puis v\u00e9rifiez que le produit install\u00e9 est conforme \u00e0 la fiche technique et aux conditions environnementales enregistr\u00e9es.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Point \u00e0 v\u00e9rifier avant l'inspection<\/th>\n<th>Pourquoi c'est important<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Temps de durcissement de la colle<\/td>\n<td>Une circulation pi\u00e9tonne trop pr\u00e9coce peut d\u00e9former les coutures ou retenir l'humidit\u00e9<\/td>\n<\/tr>\n<tr>\n<td>Code produit \/ correspondance d'\u00e9paisseur<\/td>\n<td>Confirme que c'est bien le mod\u00e8le pr\u00e9vu qui a \u00e9t\u00e9 install\u00e9, et non un produit de remplacement<\/td>\n<\/tr>\n<tr>\n<td>Journal des temp\u00e9ratures ambiantes<\/td>\n<td>Le PVC se dilate et se contracte ; une temp\u00e9rature d'installation inadapt\u00e9e entra\u00eene l'apparition de jeux.<\/td>\n<\/tr>\n<tr>\n<td>Mesure de l'humidit\u00e9 du sous-plancher<\/td>\n<td>Une humidit\u00e9 \u00e9lev\u00e9e entra\u00eene la formation de bulles et, par la suite, une perte d'adh\u00e9rence.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Je ne marche jamais sur un sol le jour m\u00eame o\u00f9 l'\u00e9quipe a fini d'\u00e9taler la colle. La plupart des colles pour PVC ont besoin d'un certain temps pour prendre, et marcher trop t\u00f4t sur le sol peut d\u00e9caler un joint qui semblait parfait une heure auparavant. Au-del\u00e0 du timing, je consulte la fiche technique du projet et je la compare ligne par ligne \u00e0 ce qui a \u00e9t\u00e9 r\u00e9ellement pos\u00e9 : code produit, \u00e9paisseur, lot de rouleaux. Cela peut sembler \u00e9l\u00e9mentaire, mais des substitutions peuvent se produire, et une \u00e9paisseur non conforme affecte \u00e0 la fois l\u2019absorption des chocs et la couverture de la garantie. Je passe \u00e9galement en revue le journal des conditions environnementales du jour de la pose : temp\u00e9rature ambiante, humidit\u00e9 de l\u2019air et taux d\u2019humidit\u00e9 du support. Le PVC r\u00e9agit \u00e0 ces conditions pendant le durcissement ; ainsi, un rev\u00eatement pos\u00e9 dans un environnement tr\u00e8s humide et sans ventilation ad\u00e9quate risque davantage de retenir de la vapeur d\u2019eau sous la surface, ce qui se traduira plus tard par des renflements ou des cloques.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-2.jpeg&quot;\" alt=\"Examen du registre environnemental avant l&#039;inspection du rev\u00eatement de sol\" \/><\/p>\n<p>Une fois que les formalit\u00e9s administratives sont r\u00e9gl\u00e9es, il est temps de se rendre sur place et de commencer \u00e0 chercher.<\/p>\n<h2>En quoi consiste une inspection visuelle d'un rev\u00eatement de sol sportif en PVC ?<\/h2>\n<p><strong>Un contr\u00f4le visuel porte sur la plan\u00e9it\u00e9, la pr\u00e9sence de bulles, l'uniformit\u00e9 de la couleur et la pr\u00e9cision des lignes de jeu \u2014 les quatre aspects les plus susceptibles de r\u00e9v\u00e9ler des erreurs de pose.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Contr\u00f4le visuel<\/th>\n<th>Ce qu'il faut rechercher<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Plan\u00e9it\u00e9 de la surface<\/td>\n<td>Cr\u00eates apparentes, d\u00e9bris sous la b\u00e2che<\/td>\n<\/tr>\n<tr>\n<td>Formation de bulles \/ cloquage<\/td>\n<td>D\u00f4mes d'air emprisonn\u00e9 vs. d\u00f4mes de vapeur d'eau<\/td>\n<\/tr>\n<tr>\n<td>Uniformit\u00e9 des couleurs<\/td>\n<td>Diff\u00e9rences de teinte entre les rouleaux, sens de d\u00e9filement incorrect<\/td>\n<\/tr>\n<tr>\n<td>Compositions des \u00e9quipes<\/td>\n<td>Ar\u00eates nettes, dimensions correctes, adh\u00e9rence de la peinture<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>Plan\u00e9it\u00e9 de la surface et formation de bulles<\/h3>\n<p>Je commence par regarder pr\u00e8s du sol, \u00e0 hauteur des yeux, et j\u2019inspecte la surface \u00e0 la recherche de \u00ab traces \u00bb \u2014 de petites cr\u00eates ou bosses l\u00e0 o\u00f9 les imperfections du sous-plancher font saillie \u00e0 travers le PVC. Cela indique g\u00e9n\u00e9ralement la pr\u00e9sence de d\u00e9bris ou un mauvais nivellement en dessous. Ensuite, je v\u00e9rifie s\u2019il y a des cloques dans les zones tr\u00e8s fr\u00e9quent\u00e9es, le long des p\u00e9rim\u00e8tres et \u00e0 proximit\u00e9 des sources de chaleur comme les fen\u00eatres ou les bouches d\u2019a\u00e9ration du syst\u00e8me de chauffage, de ventilation et de climatisation. Une cloque molle et peu profonde est souvent due \u00e0 de l\u2019air emprisonn\u00e9. Un renflement ferme qui ne s\u2019aplatit pas sous la pression est plus probablement d\u00fb \u00e0 de la vapeur d\u2019eau, ce qui constitue un probl\u00e8me plus grave car cela indique un probl\u00e8me au niveau du sous-plancher, et pas seulement une erreur de pose.<\/p>\n<h3>Couleurs et lignes de jeu<\/h3>\n<p>Je v\u00e9rifie \u00e9galement le sens de pose et l\u2019uniformit\u00e9 de la teinte, car les fabricants exigent souvent une pose dans un sens pr\u00e9cis, tant pour des raisons esth\u00e9tiques que pour \u00e9viter une usure in\u00e9gale. Je mesure ensuite les lignes de jeu par rapport aux r\u00e9glementations sportives officielles et j\u2019inspecte les bords pour d\u00e9tecter d\u2019\u00e9ventuels d\u00e9bordements de peinture ou des d\u00e9coupes irr\u00e9guli\u00e8res, car des lignes mal trac\u00e9es indiquent g\u00e9n\u00e9ralement que la peinture n\u2019a pas bien adh\u00e9r\u00e9 \u00e0 la couche sup\u00e9rieure en PUR.<\/p>\n<p>Une v\u00e9rification visuelle ne fonctionne que si l'on sait exactement \u00e0 quoi ressemble un \u00e9l\u00e9ment \u00ab conforme \u00bb pour chaque point. C'est pourquoi je travaille toujours \u00e0 partir d'une liste de contr\u00f4le \u00e9crite, et non de m\u00e9moire.<\/p>\n<h2>Que comprend la liste de contr\u00f4le pour l'inspection d'un rev\u00eatement de sol sportif en PVC ?<\/h2>\n<p><strong>Une liste de contr\u00f4le exhaustive porte sur la plan\u00e9it\u00e9, le soudage des joints, l'adh\u00e9rence, l'\u00e9paisseur, l'absorption des chocs, le marquage des lignes, l'\u00e9tat de surface, la propret\u00e9 et la documentation, chaque crit\u00e8re \u00e9tant assorti d'un crit\u00e8re de conformit\u00e9 clair.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Point d'inspection<\/th>\n<th>Crit\u00e8re de r\u00e9ussite<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Plan\u00e9it\u00e9 du sol<\/td>\n<td>Aucune ondulation ni aucune ar\u00eate visible sous une r\u00e8gle<\/td>\n<\/tr>\n<tr>\n<td>Soudage en continu<\/td>\n<td>Enti\u00e8rement soud\u00e9, sans interstices ni piq\u00fbres<\/td>\n<\/tr>\n<tr>\n<td>Adh\u00e9sion<\/td>\n<td>Pas de son creux ni de soul\u00e8vement lorsqu'on appuie dessus<\/td>\n<\/tr>\n<tr>\n<td>\u00c9paisseur<\/td>\n<td>Conforme au cahier des charges du projet<\/td>\n<\/tr>\n<tr>\n<td>Absorption des chocs<\/td>\n<td>Conforme aux exigences des normes EN 14904 et ASTM F2772<\/td>\n<\/tr>\n<tr>\n<td>Marquage au sol<\/td>\n<td>Dimensions exactes, ar\u00eates vives<\/td>\n<\/tr>\n<tr>\n<td>Finition de surface<\/td>\n<td>Pas de rayures, d'entailles ni de zones ternes<\/td>\n<\/tr>\n<tr>\n<td>Propret\u00e9<\/td>\n<td>Pas de r\u00e9sidus de colle ni de film de protection<\/td>\n<\/tr>\n<tr>\n<td>Documentation<\/td>\n<td>Guide de garantie et d'entretien re\u00e7u<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>I hand this checklist to the crew before the walk-through even starts, so nobody is guessing what &quot;acceptable&quot; means. Every item on it maps back to something I have already covered in the visual and functional checks, but writing it down as pass\/fail criteria removes the guesswork. For example, &quot;no hollow sound when pressed&quot; is something anyone on the owner&#8217;s side can test themselves with a light tap, even without training. I always attach this checklist to the final punch list, so the sign-off documentation and the inspection process line up item for item. Facility managers who keep this on file also have an easier time filing a warranty claim later, since they can point to the exact criteria the floor passed on day one.<\/p>\n<p>Une liste de contr\u00f4le vous indique ce qu'il faut v\u00e9rifier. Ce sont les joints et les soudures que je passe le plus de temps \u00e0 inspecter.<\/p>\n<h2>Comment inspecter les joints et les soudures pour d\u00e9tecter d'\u00e9ventuels d\u00e9fauts ?<\/h2>\n<p><strong>L'inspection des soudures permet de v\u00e9rifier que la m\u00e9thode de soudage appropri\u00e9e a \u00e9t\u00e9 utilis\u00e9e, de s'assurer de l'uniformit\u00e9 de la profondeur de la rainure et de d\u00e9tecter les interstices ou les piq\u00fbres par lesquels l'eau pourrait s'infiltrer.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>V\u00e9rification des coutures<\/th>\n<th>Panne<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Type de soudure<\/td>\n<td>Soudure \u00e0 froid r\u00e9alis\u00e9e alors qu'une soudure \u00e0 chaud \u00e9tait pr\u00e9vue<\/td>\n<\/tr>\n<tr>\n<td>Profondeur\/largeur de la rainure<\/td>\n<td>Canal irr\u00e9gulier avant l'insertion de la tige<\/td>\n<\/tr>\n<tr>\n<td>Pr\u00e9cision de d\u00e9coupe<\/td>\n<td>Bord sur\u00e9lev\u00e9 ou d\u00e9coupe en creux<\/td>\n<\/tr>\n<tr>\n<td>Adh\u00e9rence des joints<\/td>\n<td>Lacunes, trous d'\u00e9pingle, fusion incompl\u00e8te<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Seams are where most long-term failures start, so I give them the closest attention. First, I confirm the crew used the correct weld method \u2014 cold weld or heat weld \u2014 matching the seam spec, since using the wrong one weakens the bond over time. For heat-welded seams, I check groove depth and width before the rod was inserted; an uneven channel leads to a weak fusion point. I then look closely at the trim work. A proper two-stage trim leaves a flush cut with no gouging and no raised lip catching a rolling ball or a foot. Finally, I press along every seam and edge, feeling for gaps, pinholes, or spots where the weld did not fully fuse. Any opening here lets moisture in underneath the floor, which is one of the fastest ways to void a warranty and shorten the floor&#8217;s service life.<\/p>\n<p>Un bon \u0153il et une bonne dext\u00e9rit\u00e9 permettent de rep\u00e9rer beaucoup de choses, mais certains d\u00e9fauts ne sont visibles qu\u2019\u00e0 l\u2019aide d\u2019un instrument adapt\u00e9. Voici ce que j\u2019utilise \u00e0 chaque inspection.<\/p>\n<h2>Quels outils sont utilis\u00e9s lors de l'inspection d'un rev\u00eatement de sol en PVC ?<\/h2>\n<p><strong>Les inspecteurs utilisent une r\u00e8gle, un humidim\u00e8tre, un hygrom\u00e8tre, un testeur d'adh\u00e9rence et une source de lumi\u00e8re oblique pour d\u00e9tecter les d\u00e9fauts que les contr\u00f4les visuels seuls ne permettent pas de rep\u00e9rer.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Outil<\/th>\n<th>Objectif<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>r\u00e8gle de 2 m<\/td>\n<td>Mesure la plan\u00e9it\u00e9 et d\u00e9tecte les irr\u00e9gularit\u00e9s<\/td>\n<\/tr>\n<tr>\n<td>Humidim\u00e8tre<\/td>\n<td>Permet de mesurer l'humidit\u00e9 du support avant et apr\u00e8s la pose<\/td>\n<\/tr>\n<tr>\n<td>Hygrom\u00e8tre<\/td>\n<td>Contr\u00f4le l'humidit\u00e9 ambiante pendant le durcissement<\/td>\n<\/tr>\n<tr>\n<td>Appareil d'essai de r\u00e9sistance \u00e0 l'arrachement<\/td>\n<td>Mesure la r\u00e9sistance d'adh\u00e9rence<\/td>\n<\/tr>\n<tr>\n<td>Source lumineuse rasante<\/td>\n<td>Permet de d\u00e9tecter les d\u00e9fauts de surface invisibles sous un \u00e9clairage plat<\/td>\n<\/tr>\n<tr>\n<td>Jauge d'\u00e9paisseur<\/td>\n<td>V\u00e9rifie la largeur de l'\u00e9cart entre les joints<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>A 2m straightedge laid across the floor tells me more about flatness than eyeballing ever will \u2014 any gap underneath the edge points to a ridge or a dip that will telegraph over time. A moisture meter is non-negotiable on any project with a concrete subfloor, since readings above the manufacturer&#8217;s threshold mean the adhesive bond is at risk even if the surface looks fine today. I also carry a pull-off tester for spot-checking adhesion strength on higher-risk projects, especially gymnasiums with heavy rolling equipment. One tool that gets overlooked is a simple raking light \u2014 a handheld light held low and angled across the surface. It throws shadows across bumps, scratches, and seam irregularities that are invisible under normal overhead lighting. None of these tools replace a trained eye, but they turn a subjective call into a documented, repeatable measurement.<\/p>\n<p>Une fois que l'on dispose des outils ad\u00e9quats, l'\u00e9tape suivante consiste \u00e0 v\u00e9rifier que le sol r\u00e9pond bien aux exigences pr\u00e9vues par les normes.<\/p>\n<h2>Quels tests physiques et fonctionnels permettent de v\u00e9rifier les performances au sol ?<\/h2>\n<p><strong>Les essais de pression d'adh\u00e9rence, les contr\u00f4les d'absorption des chocs conform\u00e9ment aux normes EN 14904 et ASTM F2772, ainsi que les essais de r\u00e9sistance au glissement, confirment que le rev\u00eatement de sol r\u00e9pond aux exigences des normes, et ne se contente pas d'avoir un aspect conforme.<\/strong><\/p>\n<p>I press firmly along seams and edges across the whole court, feeling for any spot that lifts or flexes \u2014 that tells me if the adhesive bonded fully or if a section is still loose underneath. I also check shock absorption and ball rebound consistency across different zones of the court, referencing EN 14904 or ASTM F2772 depending on the project&#8217;s required standard. These specs exist for a reason: inconsistent rebound or shock absorption across a court creates uneven playing conditions and, over time, higher injury risk for athletes making repeated impact movements. Last, I check slip resistance. Excess adhesive residue or an incomplete initial clean can leave slick spots, and I always verify the matte or anti-glare finish looks correct under the venue&#8217;s actual overhead lighting, not just daylight from an open door.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-1.jpeg&quot;\" alt=\"Essais d&#039;absorption des chocs et de r\u00e9sistance au glissement\" \/><\/p>\n<p>Ces deux normes sont souvent cit\u00e9es, mais elles ne sont pas interchangeables. Voici ce que chacune d'elles mesure r\u00e9ellement.<\/p>\n<h2>Quelles sont les normes utilis\u00e9es pour la r\u00e9ception des rev\u00eatements de sol sportifs en PVC ?<\/h2>\n<p><strong>La norme EN 14904 \u00e9value l'absorption des chocs, la d\u00e9formation verticale, le rebond de la balle et le frottement ; la norme ASTM F2772 porte quant \u00e0 elle sur la r\u00e9duction des forces et la d\u00e9formation verticale pour les rev\u00eatements de sols destin\u00e9s aux sports en salle.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Standard<\/th>\n<th>R\u00e9gion<\/th>\n<th>Indicateurs cl\u00e9s<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>EN 14904<\/td>\n<td>Europe \/ International<\/td>\n<td>Absorption des chocs, d\u00e9formation verticale, rebond de la balle, frottement<\/td>\n<\/tr>\n<tr>\n<td>ASTM F2772<\/td>\n<td>Am\u00e9rique du Nord<\/td>\n<td>R\u00e9duction de la force, d\u00e9formation verticale<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>La norme EN 14904 est la r\u00e9f\u00e9rence \u00e0 laquelle se conforment la plupart des projets hors d\u2019Am\u00e9rique du Nord ; elle couvre un large \u00e9ventail d\u2019indicateurs de performance : la capacit\u00e9 d\u2019absorption des chocs du sol lors d\u2019un impact, la d\u00e9formation verticale de la surface sous charge, l\u2019uniformit\u00e9 du rebond d\u2019une balle sur l\u2019ensemble du terrain, ainsi que le niveau de frottement offert par la surface sous le pied. La norme ASTM F2772 est celle que je rencontre le plus souvent dans les projets nord-am\u00e9ricains ; elle se concentre sp\u00e9cifiquement sur la r\u00e9duction des forces et la d\u00e9formation verticale, car ces deux param\u00e8tres sont ceux qui sont le plus directement li\u00e9s au risque de blessure des athl\u00e8tes lors d\u2019atterrissages brutaux. Aucune de ces normes n\u2019est intrins\u00e8quement \u00ab meilleure \u00bb : le choix de la norme appropri\u00e9e d\u00e9pend de la f\u00e9d\u00e9ration sportive, de la r\u00e9gion et, parfois, des exigences en mati\u00e8re d\u2019assurance li\u00e9es \u00e0 l\u2019installation. Lors de l\u2019inspection, l\u2019important est de v\u00e9rifier que les r\u00e9sultats des essais consign\u00e9s correspondent bien \u00e0 la norme requise par le cahier des charges du projet, et pas seulement de s\u2019assurer de l\u2019existence d\u2019un certificat.<\/p>\n<p>Acceptance tolerances for flatness, seam height, and line marking should always follow the project specification, the manufacturer&#8217;s installation guide, and any local building code \u2014 I avoid quoting a fixed number here because it changes project to project, and applying the wrong tolerance can create disputes that were never really about the floor.<\/p>\n<p>M\u00eame lorsque toutes les normes sont respect\u00e9es, certains d\u00e9fauts apparaissent tout de m\u00eame. Voici comment je d\u00e9termine leur origine.<\/p>\n<h2>Quels sont les d\u00e9fauts les plus courants et comment y rem\u00e9dier ?<\/h2>\n<p><strong>La plupart des d\u00e9fauts sont dus \u00e0 la pr\u00e9sence d'air emprisonn\u00e9, \u00e0 une temp\u00e9rature de soudage inadapt\u00e9e, \u00e0 une mauvaise pr\u00e9paration du support ou \u00e0 des r\u00e9sidus de colle \u2014 chacun de ces probl\u00e8mes pouvant \u00eatre r\u00e9solu de mani\u00e8re sp\u00e9cifique et cibl\u00e9e.<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>D\u00e9faut constat\u00e9<\/th>\n<th>Cause probable<\/th>\n<th>Assainissement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Formation de bulles localis\u00e9e<\/td>\n<td>Pr\u00e9sence d'air emprisonn\u00e9 ou application tardive de la colle<\/td>\n<td>Injection d'adh\u00e9sif ou remplacement d'une section<\/td>\n<\/tr>\n<tr>\n<td>S\u00e9paration des coutures \/ petits trous<\/td>\n<td>Chaleur de soudure incorrecte ou mauvais ajustement de la lame<\/td>\n<td>Resoudage d'un segment ou r\u00e9paration d'un joint<\/td>\n<\/tr>\n<tr>\n<td>Irr\u00e9gularit\u00e9s visibles du sous-plancher<\/td>\n<td>Nivellement insuffisant du sous-plancher<\/td>\n<td>Relevage partiel du rouleau, mise \u00e0 niveau, recollage<\/td>\n<\/tr>\n<tr>\n<td>Zones brillantes \/ glissantes<\/td>\n<td>R\u00e9sidus d'agent de d\u00e9moulage ou traces de colle<\/td>\n<td>Nettoyage en profondeur avec un produit nettoyant pour sols au pH neutre<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>I keep this matrix on hand during every walk-through because it turns a vague complaint like &quot;the floor looks off here&quot; into a specific cause and a specific fix. Localized bubbling, for example, almost always means either trapped air during rolling or the crew placed the sheet too late into the adhesive&#8217;s open time \u2014 the fix is a targeted adhesive injection or, in worse cases, replacing that section. Seam separation usually traces back to incorrect weld heat or a poor blade trim, so I send that seam back for re-welding rather than patching over it. Subfloor ridges mean the leveling work underneath was not adequate, which requires lifting that section, releveling, and re-gluing. Shiny or slippery patches are almost always leftover manufacturing release agent or adhesive smudge, solved with a proper pH-neutral deep scrub rather than assuming it is a material defect.<\/p>\n<p>Une fois que tous les points de cette liste auront \u00e9t\u00e9 r\u00e9gl\u00e9s, la derni\u00e8re \u00e9tape consistera \u00e0 officialiser le transfert.<\/p>\n<h2>Comment proc\u00e9der \u00e0 la r\u00e9ception et au transfert des t\u00e2ches de maintenance ?<\/h2>\n<p><strong>La r\u00e9ception d\u00e9finitive n\u00e9cessite la remise d'un relev\u00e9 des travaux \u00e0 terminer accompagn\u00e9 de photos, la validation des \u00e9tapes de nettoyage initiales, ainsi que la remise des documents de garantie et d'entretien avant le paiement final.<\/strong><\/p>\n<p>Je ne cl\u00f4ture jamais un projet sans \u00e9tablir une liste \u00e9crite des travaux \u00e0 rectifier \u2014 avec des photos claires, les num\u00e9ros de rouleau et les d\u00e9lais de correction pour tout ce qui n\u2019a pas pass\u00e9 l\u2019inspection. Cela prot\u00e8ge \u00e0 la fois le ma\u00eetre d\u2019ouvrage et l\u2019entrepreneur si un litige venait \u00e0 survenir par la suite. Avant le premier nettoyage humide, je v\u00e9rifie le d\u00e9lai d\u2019attente requis et m\u2019assure que l\u2019\u00e9quipe d\u2019entretien conna\u00eet les produits de nettoyage autoris\u00e9s, car les solvants agressifs peuvent endommager la couche d\u2019usure en PUR et annuler la garantie d\u00e8s la premi\u00e8re ann\u00e9e. La remise des cl\u00e9s implique \u00e9galement la remise physique du certificat de garantie, d\u2019un calendrier d\u2019entretien et de tout reste de rouleau mis de c\u00f4t\u00e9 pour de futures r\u00e9parations. Cette derni\u00e8re \u00e9tape est trop souvent n\u00e9glig\u00e9e, et c\u2019est g\u00e9n\u00e9ralement la premi\u00e8re chose dont un responsable des installations regrette de ne pas disposer deux ans plus tard, lorsqu\u2019une r\u00e9paration s\u2019av\u00e8re n\u00e9cessaire et que le lot exact de rouleaux est introuvable.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-4.jpeg&quot;\" alt=\"Documents de r\u00e9ception d\u00e9finitive et de transfert des responsabilit\u00e9s en mati\u00e8re de maintenance\" \/><\/p>\n<p>Avant de conclure, permettez-moi de r\u00e9pondre \u00e0 quelques questions qui me sont pos\u00e9es dans le cadre de presque tous les projets.<\/p>\n<h2>Questions fr\u00e9quemment pos\u00e9es<\/h2>\n<p><strong>Dans quel d\u00e9lai faut-il inspecter un rev\u00eatement de sol sportif en PVC apr\u00e8s sa pose ?<\/strong><br \/>\nAttendez au moins 24 \u00e0 72 heures apr\u00e8s la pose, une fois que la colle a compl\u00e8tement durci, avant de proc\u00e9der \u00e0 une inspection compl\u00e8te des lieux.<\/p>\n<p><strong>Quelles sont les causes de l'\u00e9chec des rev\u00eatements de sol sportifs en PVC lors des contr\u00f4les ?<\/strong><br \/>\nLes causes les plus courantes sont la pr\u00e9sence d'air ou d'humidit\u00e9 emprisonn\u00e9s sous la surface, une chaleur de soudure inadapt\u00e9e au niveau des joints, un nivellement irr\u00e9gulier du sous-plancher et la pr\u00e9sence de r\u00e9sidus de colle sur la surface.<\/p>\n<p><strong>Peut-on r\u00e9parer les bulles qui apparaissent sur un rev\u00eatement de sol en PVC ?<\/strong><br \/>\nOui. Les petites bulles d'air emprisonn\u00e9es sont g\u00e9n\u00e9ralement \u00e9limin\u00e9es par injection d'adh\u00e9sif. Les renflements plus importants dus \u00e0 la vapeur d'eau n\u00e9cessitent souvent de soulever et de remplacer la partie concern\u00e9e.<\/p>\n<p><strong>Comment v\u00e9rifier si un rev\u00eatement de sol sportif en vinyle est correctement coll\u00e9 ?<\/strong><br \/>\nAppuyez fermement le long des joints et sur les zones libres, puis \u00e9coutez si un son creux se fait entendre ; vous pouvez \u00e9galement utiliser un testeur d'adh\u00e9rence pour obtenir une mesure pr\u00e9cise de la r\u00e9sistance \u00e0 l'arrachement.<\/p>\n<p><strong>Qui est responsable des d\u00e9fauts du rev\u00eatement de sol apr\u00e8s la pose ?<\/strong><br \/>\nL'entrepreneur charg\u00e9 de l'installation est g\u00e9n\u00e9ralement responsable des d\u00e9fauts constat\u00e9s lors de la visite de fin de chantier ; c'est pourquoi il est important de consigner les probl\u00e8mes \u00e0 l'aide de photos et d'indiquer les num\u00e9ros de rouleau avant le paiement final.<\/p>\n<h2>Conclusion<\/h2>\n<p>Une inspection minutieuse garantit la s\u00e9curit\u00e9, la jouabilit\u00e9 et le retour sur investissement : ne versez jamais le solde final avant que tous les points de la liste des travaux \u00e0 r\u00e9aliser aient \u00e9t\u00e9 r\u00e9gl\u00e9s.<\/p>","protected":false},"excerpt":{"rendered":"<p>A proper post-installation inspection checks four things: surface flatness, seam integrity, adhesion, and standard compliance (EN 14904 \/ ASTM F2772). Skipping this step risks athlete safety, voided warranties, and early floor failure. I have walked hundreds of finished courts before final sign-off, and I can tell you this: a floor that looks good from the&#8230;<\/p>","protected":false},"author":4,"featured_media":9546,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-9538","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pvc-floor-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How Do Contractors Inspect Installed PVC Sports Flooring - MF FLOOR<\/title>\n<meta name=\"description\" content=\"Learn how contractors inspect PVC sports flooring after installation, including seams, flatness, adhesion, defects, and standards.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/meettfit.com\/fr\/pvc-floor-blog\/comment-les-entrepreneurs-procedent-ils-a-linspection-des-revetements-de-sol-sportifs-en-pvc-deja-poses\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Do Contractors Inspect Installed PVC Sports Flooring - MF FLOOR\" \/>\n<meta property=\"og:description\" content=\"Learn how contractors inspect PVC sports flooring after installation, including seams, flatness, adhesion, defects, and standards.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/meettfit.com\/fr\/pvc-floor-blog\/comment-les-entrepreneurs-procedent-ils-a-linspection-des-revetements-de-sol-sportifs-en-pvc-deja-poses\/\" \/>\n<meta property=\"og:site_name\" content=\"MF FLOOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-23T09:00:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Leo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Leo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/\"},\"author\":{\"name\":\"Leo\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\"},\"headline\":\"How Do Contractors Inspect Installed PVC Sports Flooring\",\"datePublished\":\"2026-07-23T09:00:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/\"},\"wordCount\":2511,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg\",\"articleSection\":[\"Vinyl Flooring Insights\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/\",\"url\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/\",\"name\":\"How Do Contractors Inspect Installed PVC Sports Flooring - MF FLOOR\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg\",\"datePublished\":\"2026-07-23T09:00:45+00:00\",\"description\":\"Learn how contractors inspect PVC sports flooring after installation, including seams, flatness, adhesion, defects, and standards.\",\"breadcrumb\":{\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg\",\"width\":800,\"height\":600,\"caption\":\"PVC Sports Flooring (3)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/meettfit.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Do Contractors Inspect Installed PVC Sports Flooring\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/meettfit.com\/#website\",\"url\":\"https:\/\/meettfit.com\/\",\"name\":\"MF FLOOR\",\"description\":\"fitness and sports floor China factory\",\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"alternateName\":\"MF FLOOR\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/meettfit.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/meettfit.com\/#organization\",\"name\":\"MF FLOOR\",\"alternateName\":\"MF FLOOR\",\"url\":\"https:\/\/meettfit.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"width\":512,\"height\":512,\"caption\":\"MF FLOOR\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\",\"name\":\"Leo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/848b16970688cfb2f4cc64e85a2e2233183d3242ed0a21ffa4c859df339031f6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/848b16970688cfb2f4cc64e85a2e2233183d3242ed0a21ffa4c859df339031f6?s=96&d=mm&r=g\",\"caption\":\"Leo\"},\"url\":\"https:\/\/meettfit.com\/fr\/author\/1659230944qq-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How Do Contractors Inspect Installed PVC Sports Flooring - MF FLOOR","description":"Learn how contractors inspect PVC sports flooring after installation, including seams, flatness, adhesion, defects, and standards.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/meettfit.com\/fr\/pvc-floor-blog\/comment-les-entrepreneurs-procedent-ils-a-linspection-des-revetements-de-sol-sportifs-en-pvc-deja-poses\/","og_locale":"fr_FR","og_type":"article","og_title":"How Do Contractors Inspect Installed PVC Sports Flooring - MF FLOOR","og_description":"Learn how contractors inspect PVC sports flooring after installation, including seams, flatness, adhesion, defects, and standards.","og_url":"https:\/\/meettfit.com\/fr\/pvc-floor-blog\/comment-les-entrepreneurs-procedent-ils-a-linspection-des-revetements-de-sol-sportifs-en-pvc-deja-poses\/","og_site_name":"MF FLOOR","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100079773047357","article_published_time":"2026-07-23T09:00:45+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg","type":"image\/jpeg"}],"author":"Leo","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Leo","Dur\u00e9e de lecture estim\u00e9e":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#article","isPartOf":{"@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/"},"author":{"name":"Leo","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef"},"headline":"How Do Contractors Inspect Installed PVC Sports Flooring","datePublished":"2026-07-23T09:00:45+00:00","mainEntityOfPage":{"@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/"},"wordCount":2511,"commentCount":0,"publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"image":{"@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg","articleSection":["Vinyl Flooring Insights"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/","url":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/","name":"How Do Contractors Inspect Installed PVC Sports Flooring - MF FLOOR","isPartOf":{"@id":"https:\/\/meettfit.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage"},"image":{"@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg","datePublished":"2026-07-23T09:00:45+00:00","description":"Learn how contractors inspect PVC sports flooring after installation, including seams, flatness, adhesion, defects, and standards.","breadcrumb":{"@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#primaryimage","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/07\/PVC-Sports-Flooring-3.jpeg","width":800,"height":600,"caption":"PVC Sports Flooring (3)"},{"@type":"BreadcrumbList","@id":"https:\/\/meettfit.com\/pvc-floor-blog\/how-do-contractors-inspect-installed-pvc-sports-flooring\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/meettfit.com\/"},{"@type":"ListItem","position":2,"name":"How Do Contractors Inspect Installed PVC Sports Flooring"}]},{"@type":"WebSite","@id":"https:\/\/meettfit.com\/#website","url":"https:\/\/meettfit.com\/","name":"MF FLOOR","description":"fitness and sports floor China factory","publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"alternateName":"MF FLOOR","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/meettfit.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/meettfit.com\/#organization","name":"MF FLOOR","alternateName":"MF FLOOR","url":"https:\/\/meettfit.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","width":512,"height":512,"caption":"MF FLOOR"},"image":{"@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100079773047357"]},{"@type":"Person","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef","name":"Leo","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/848b16970688cfb2f4cc64e85a2e2233183d3242ed0a21ffa4c859df339031f6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/848b16970688cfb2f4cc64e85a2e2233183d3242ed0a21ffa4c859df339031f6?s=96&d=mm&r=g","caption":"Leo"},"url":"https:\/\/meettfit.com\/fr\/author\/1659230944qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts\/9538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/comments?post=9538"}],"version-history":[{"count":1,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts\/9538\/revisions"}],"predecessor-version":[{"id":9549,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts\/9538\/revisions\/9549"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/media\/9546"}],"wp:attachment":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/media?parent=9538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/categories?post=9538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/tags?post=9538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}