{"id":7991,"date":"2026-03-28T15:07:03","date_gmt":"2026-03-28T07:07:03","guid":{"rendered":"https:\/\/meettfit.com\/?p=7991"},"modified":"2026-04-09T15:12:32","modified_gmt":"2026-04-09T07:12:32","slug":"what-moisture-level-is-acceptable-before-installing-rubber-flooring","status":"publish","type":"post","link":"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/quel-est-le-niveau-dhumidite-acceptable-avant-la-pose-dun-revetement-de-sol-en-caoutchouc\/","title":{"rendered":"Quel est le niveau d'humidit\u00e9 acceptable avant la pose d'un rev\u00eatement de sol en caoutchouc ?"},"content":{"rendered":"<p><strong>Pour les sous-planchers en b\u00e9ton, le niveau d'humidit\u00e9 acceptable est g\u00e9n\u00e9ralement inf\u00e9rieur \u00e0 75%-80% d'humidit\u00e9 relative (HR) ou inf\u00e9rieur \u00e0 5 lbs MVER. Les sous-planchers en bois doivent rester entre 6% et 12%. Ces limites varient en fonction de l'adh\u00e9sif utilis\u00e9 et du choix de l'installation (coll\u00e9e ou \u00e0 embo\u00eetement).<\/strong><\/p>\n<p>Le seuil d'humidit\u00e9 sp\u00e9cifique \u00e0 votre projet n'est pas un chiffre universel unique car il d\u00e9pend de la tol\u00e9rance chimique de votre agent de liaison. Bien que 80% RH soit une r\u00e9f\u00e9rence standard, de nombreux adh\u00e9sifs modernes \u00e0 forte humidit\u00e9 permettent des installations sur b\u00e9ton jusqu'\u00e0 95% ou m\u00eame 99% RH. Si vous utilisez un syst\u00e8me de pose libre ou d'embo\u00eetement sans colle, l'humidit\u00e9 du support est moins critique pour l'adh\u00e9rence, mais reste essentielle pour \u00e9viter les moisissures et les odeurs de \"renferm\u00e9\" pi\u00e9g\u00e9es sous le caoutchouc non poreux. Vous devez toujours donner la priorit\u00e9 \u00e0 la fiche technique fournie par le fabricant plut\u00f4t qu'aux estimations g\u00e9n\u00e9rales de l'industrie. Ignorer ces sp\u00e9cificit\u00e9s entra\u00eene une r\u00e9\u00e9mulsification de l'adh\u00e9sif, c'est-\u00e0-dire que la colle redevient liquide et fait bouger le rev\u00eatement de sol. J'ai vu un nombre incalculable de sols de gymnases \u00e9chouer parce que l'installateur avait regard\u00e9 une surface s\u00e8che mais n'avait pas tenu compte de la pression de vapeur qui s'accumulait \u00e0 l'int\u00e9rieur de la dalle. La pr\u00e9cision technique au d\u00e9part est le seul moyen de prot\u00e9ger l'int\u00e9grit\u00e9 \u00e0 long terme du caoutchouc.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-6-4.jpeg&quot;\" alt=\"test d&#039;humidit\u00e9 du sous-sol pour les rev\u00eatements de sol en caoutchouc\" \/><\/p>\n<p>Les donn\u00e9es suivantes r\u00e9sument les limites acceptables pour diff\u00e9rents mat\u00e9riaux et m\u00e9thodes d'installation afin de vous aider \u00e0 d\u00e9cider si votre site est pr\u00eat.<\/p>\n<h2>Quelles sont les limites acceptables pour mon sous-plancher sp\u00e9cifique ?<\/h2>\n<p><strong>Les niveaux d'humidit\u00e9 acceptables sont strictement d\u00e9finis par le type de sous-plancher : le b\u00e9ton coll\u00e9 exige une HR &lt;80%, tandis que le bois doit avoir une HR de 6%-12%. Les dalles \u00e0 embo\u00eetement sont plus tol\u00e9rantes, mais n\u00e9cessitent tout de m\u00eame un environnement stable pour \u00e9viter la pourriture du sous-plancher ou les probl\u00e8mes de dilatation une fois la pose termin\u00e9e.<\/strong><\/p>\n<p>When I manage a large-scale installation, I categorize the subfloor to determine the risk level. Concrete slabs, especially those on the ground floor or <a href=\"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/les-revetements-de-sol-en-caoutchouc-sont-ils-surs-pour-les-sous-sols-humides\/\">in basements with moisture and humidity<\/a>, are prone to &quot;vapor drive,&quot; where moisture moves from the soil through the concrete pores. If this vapor is trapped by non-breathable rubber, it creates osmotic pressure that causes visible bubbling. Wood subfloors require a different focus; they are organic and will warp if the moisture content is not within 4% of the rubber flooring&#8217;s acclimated state. For interlocking systems, the &quot;acceptable&quot; level is higher because there is no adhesive to fail, but you must still ensure the subfloor is dry enough to prevent bacteria growth. Using a pin-type meter for wood and in-situ probes for concrete provides the precise data needed to avoid these structural failures. Use the matrix below to match your project scenario with the required safety limits.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Type de sous-plancher<\/th>\n<th style=\"text-align: left;\">M\u00e9thode d'installation<\/th>\n<th style=\"text-align: left;\">Taux d'humidit\u00e9 acceptable<\/th>\n<th style=\"text-align: left;\">M\u00e9thode d'essai primaire<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>B\u00e9ton<\/strong><\/td>\n<td style=\"text-align: left;\">Collage standard<\/td>\n<td style=\"text-align: left;\">&lt; 75% &#8211; 80% RH \/ &lt; 3-5 lbs MVER<\/td>\n<td style=\"text-align: left;\">ASTM F2170 (sondes d'humidit\u00e9 relative)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>B\u00e9ton<\/strong><\/td>\n<td style=\"text-align: left;\">Colle \u00e0 forte teneur en humidit\u00e9<\/td>\n<td style=\"text-align: left;\">&lt; 90% &#8211; 99% RH<\/td>\n<td style=\"text-align: left;\">Fiche technique de l'adh\u00e9sif<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>B\u00e9ton<\/strong><\/td>\n<td style=\"text-align: left;\">Carreaux \u00e0 embo\u00eetement<\/td>\n<td style=\"text-align: left;\">&lt; 85% RH (pare-vapeur recommand\u00e9)<\/td>\n<td style=\"text-align: left;\">Test de la feuille de plastique<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Bois \/ Contreplaqu\u00e9<\/strong><\/td>\n<td style=\"text-align: left;\">Toute m\u00e9thode<\/td>\n<td style=\"text-align: left;\">6% &#8211; 12% Moisture Content<\/td>\n<td style=\"text-align: left;\">Humidim\u00e8tre \u00e0 broche<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Dalle de sous-sol<\/strong><\/td>\n<td style=\"text-align: left;\">Toute m\u00e9thode<\/td>\n<td style=\"text-align: left;\">Test d'entra\u00eenement actif de la vapeur<\/td>\n<td style=\"text-align: left;\">Test sur le chlorure de calcium<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-5-4.jpeg&quot;\" alt=\"mesure de l&#039;humidit\u00e9 sur le contreplaqu\u00e9 et le b\u00e9ton\" \/><\/p>\n<p>Si vos relev\u00e9s actuels d\u00e9passent ces valeurs, vous devez mettre en \u0153uvre une strat\u00e9gie d'att\u00e9nuation avant de proc\u00e9der \u00e0 l'application du caoutchouc.<\/p>\n<h2>Comment r\u00e9soudre les probl\u00e8mes de forte humidit\u00e9 avant l'installation ?<\/h2>\n<p><strong>Pour rem\u00e9dier \u00e0 une humidit\u00e9 \u00e9lev\u00e9e, vous devez appliquer un pare-vapeur liquide, utiliser des adh\u00e9sifs sp\u00e9cialis\u00e9s \u00e0 haute r\u00e9sistance \u00e0 l'humidit\u00e9 ou opter pour un syst\u00e8me d'embo\u00eetement flottant. En outre, il est n\u00e9cessaire d'acclimater le caoutchouc dans la pi\u00e8ce pendant 48 \u00e0 72 heures afin de stabiliser le mat\u00e9riau par rapport \u00e0 l'environnement du sous-plancher.<\/strong><\/p>\n<p>Lorsqu'un sous-plancher \u00e9choue au test d'humidit\u00e9, je cherche des solutions techniques pour respecter le calendrier du projet. Un pare-vapeur liquide est la solution la plus efficace pour le b\u00e9ton ; il cr\u00e9e un joint non poreux qui bloque tout mouvement de vapeur. Si le budget ne permet pas l'application d'un pare-vapeur complet, l'utilisation d'un adh\u00e9sif ur\u00e9thane haute performance peut r\u00e9soudre le probl\u00e8me pour les dalles jusqu'\u00e0 95% HR. Pour les sous-sols r\u00e9sidentiels o\u00f9 l'humidit\u00e9 est constante, je sugg\u00e8re d'utiliser des dalles \u00e0 embo\u00eetement plut\u00f4t que des rouleaux \u00e0 coller. Cela permet au support de \"respirer\" \u00e0 travers les joints, \u00e9vitant ainsi la pression de gaz qui provoque des bulles dans les sols coll\u00e9s. Quel que soit l'\u00e9tat du support, le caoutchouc doit rester d\u00e9roul\u00e9 dans l'espace de pose pendant au moins deux jours. Cette acclimatation permet au caoutchouc d'atteindre une temp\u00e9rature et un niveau d'humidit\u00e9 stables, ce qui emp\u00eache le sol de se r\u00e9tracter ou de se dilater une fois les bords coup\u00e9s et finis.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Probl\u00e8me d'humidit\u00e9<\/th>\n<th style=\"text-align: left;\">Solution professionnelle<\/th>\n<th style=\"text-align: left;\">B\u00e9n\u00e9fice principal<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Taux d'humidit\u00e9 excessif du b\u00e9ton<\/strong><\/td>\n<td style=\"text-align: left;\">Barri\u00e8re vapeur liquide (MVB)<\/td>\n<td style=\"text-align: left;\">Etanch\u00e9it\u00e9 permanente \u00e0 la vapeur<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Un calendrier serr\u00e9 pour le projet<\/strong><\/td>\n<td style=\"text-align: left;\">Colle ur\u00e9thane \u00e0 haute teneur en humidit\u00e9<\/td>\n<td style=\"text-align: left;\">Installation plus rapide sur les dalles humides<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Humidit\u00e9 constante du sous-sol<\/strong><\/td>\n<td style=\"text-align: left;\">Plancher flottant \u00e0 embo\u00eetement<\/td>\n<td style=\"text-align: left;\">Permet au support de respirer<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Instabilit\u00e9 des mat\u00e9riaux<\/strong><\/td>\n<td style=\"text-align: left;\">Acclimatation de 48 \u00e0 72 heures<\/td>\n<td style=\"text-align: left;\">Pr\u00e9vient les lacunes apr\u00e8s l'installation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-1-4.jpeg&quot;\" alt=\"installation d&#039;une barri\u00e8re anti-humidit\u00e9\" \/><\/p>\n<p>Avant de commencer l'application finale, utilisez cette liste de contr\u00f4le technique pour confirmer que toutes les conditions environnementales et mat\u00e9rielles sont remplies.<\/p>\n<h2>Liste de contr\u00f4le finale avant installation : Votre site est-il pr\u00eat ?<\/h2>\n<p><strong>Avant de commencer, v\u00e9rifiez que vos relev\u00e9s d'humidit\u00e9 correspondent aux sp\u00e9cifications du fabricant de l'adh\u00e9sif. Vous devez \u00e9galement vous assurer que le syst\u00e8me de chauffage, de ventilation et de climatisation a fonctionn\u00e9 pendant 7 jours, que le sous-plancher est exempt de d\u00e9bris et que le caoutchouc s'est acclimat\u00e9 pendant au moins 48 heures.<\/strong><\/p>\n<p>I do not allow an installation to begin until the HVAC system has stabilized the room&#8217;s climate. The temperature and air humidity directly influence how the subfloor releases moisture and how the adhesive cures. If the room is too cold, the glue will not bond; if it is too humid, the concrete will not dry. The subfloor must also be properly <a href=\"https:\/\/meettfit.com\/fr\/sols-commerciaux-savoir\/comment-niveler-le-beton-pour-linstallation-dun-revetement-de-sol-en-caoutchouc\/\">leveled and prepared<\/a> to remove old paint, wax, or curing compounds that might interfere with the bond. Finally, ensure the rubber is laid out flat to remove any &quot;memory&quot; from the rolls. This preparation prevents the most common field failures I encounter, such as seam separation and adhesive release. Documenting your final moisture readings is essential for warranty protection and ensures a professional result that lasts for the life of the facility.<\/p>\n<ul>\n<li class=\"gfm-task-list\"><input type=\"checkbox\">Recouper les relev\u00e9s RH\/MVER avec la fiche technique de l'adh\u00e9sif.<\/li>\n<li class=\"gfm-task-list\"><input type=\"checkbox\">Ensure wood subfloor is within 4% of the rubber&#8217;s moisture content.<\/li>\n<li class=\"gfm-task-list\"><input type=\"checkbox\">Faire fonctionner le syst\u00e8me CVC \u00e0 la temp\u00e9rature normale d'occupation pendant 7 jours cons\u00e9cutifs.<\/li>\n<li class=\"gfm-task-list\"><input type=\"checkbox\">Enlever toute la poussi\u00e8re, la graisse et les anciens contaminants de la surface du sous-plancher.<\/li>\n<li class=\"gfm-task-list\"><input type=\"checkbox\">Acclimater tous les mat\u00e9riaux en caoutchouc dans l'espace d'installation pendant 48 \u00e0 72 heures.<\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-3-4.jpeg&quot;\" alt=\"liste de contr\u00f4le de l&#039;installation professionnelle\" \/><\/p>\n<h2>Conclusion<\/h2>\n<p><strong>Les niveaux d'humidit\u00e9 acceptables d\u00e9pendent du support et de la m\u00e9thode de pose. Il faut toujours maintenir le b\u00e9ton sous 80% RH et le bois sous 12% pour assurer une liaison s\u00fbre et permanente.<\/strong><\/p>","protected":false},"excerpt":{"rendered":"<p>For concrete subfloors, the acceptable moisture level is typically below 75%\u201380% Relative Humidity (RH) or under 5 lbs MVER. Wood subfloors must stay between 6% and 12%. These limits change based on your specific adhesive and whether you choose a glue-down or interlocking installation. The specific moisture threshold for your project is not a single&#8230;<\/p>","protected":false},"author":4,"featured_media":7996,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[25],"tags":[],"class_list":["post-7991","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-acoustic-underlay"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>What Moisture Level Is Acceptable Before Installing Rubber Flooring - MF FLOOR<\/title>\n<meta name=\"description\" content=\"Learn the acceptable moisture level before installing rubber flooring. See RH, MVER, wood subfloor limits, and how to avoid adhesive failure.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/quel-est-le-niveau-dhumidite-acceptable-avant-la-pose-dun-revetement-de-sol-en-caoutchouc\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Moisture Level Is Acceptable Before Installing Rubber Flooring - MF FLOOR\" \/>\n<meta property=\"og:description\" content=\"Learn the acceptable moisture level before installing rubber flooring. See RH, MVER, wood subfloor limits, and how to avoid adhesive failure.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/quel-est-le-niveau-dhumidite-acceptable-avant-la-pose-dun-revetement-de-sol-en-caoutchouc\/\" \/>\n<meta property=\"og:site_name\" content=\"MF FLOOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-28T07:07:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-09T07:12:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"1659230944@qq.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"1659230944@qq.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/\"},\"author\":{\"name\":\"1659230944@qq.com\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\"},\"headline\":\"What Moisture Level Is Acceptable Before Installing Rubber Flooring\",\"datePublished\":\"2026-03-28T07:07:03+00:00\",\"dateModified\":\"2026-04-09T07:12:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/\"},\"wordCount\":1047,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg\",\"articleSection\":[\"Soundproof Flooring Solutions\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/\",\"url\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/\",\"name\":\"What Moisture Level Is Acceptable Before Installing Rubber Flooring - MF FLOOR\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg\",\"datePublished\":\"2026-03-28T07:07:03+00:00\",\"dateModified\":\"2026-04-09T07:12:32+00:00\",\"description\":\"Learn the acceptable moisture level before installing rubber flooring. See RH, MVER, wood subfloor limits, and how to avoid adhesive failure.\",\"breadcrumb\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg\",\"width\":800,\"height\":600,\"caption\":\"Rubber Flooring (4)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/meettfit.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Moisture Level Is Acceptable Before Installing Rubber Flooring\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/meettfit.com\/#website\",\"url\":\"https:\/\/meettfit.com\/\",\"name\":\"MF FLOOR\",\"description\":\"fitness and sports floor China factory\",\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"alternateName\":\"MF FLOOR\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/meettfit.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/meettfit.com\/#organization\",\"name\":\"MF FLOOR\",\"alternateName\":\"MF FLOOR\",\"url\":\"https:\/\/meettfit.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"width\":512,\"height\":512,\"caption\":\"MF FLOOR\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\",\"name\":\"1659230944@qq.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"caption\":\"1659230944@qq.com\"},\"url\":\"https:\/\/meettfit.com\/fr\/author\/1659230944qq-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"What Moisture Level Is Acceptable Before Installing Rubber Flooring - MF FLOOR","description":"Learn the acceptable moisture level before installing rubber flooring. See RH, MVER, wood subfloor limits, and how to avoid adhesive failure.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/quel-est-le-niveau-dhumidite-acceptable-avant-la-pose-dun-revetement-de-sol-en-caoutchouc\/","og_locale":"fr_FR","og_type":"article","og_title":"What Moisture Level Is Acceptable Before Installing Rubber Flooring - MF FLOOR","og_description":"Learn the acceptable moisture level before installing rubber flooring. See RH, MVER, wood subfloor limits, and how to avoid adhesive failure.","og_url":"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/quel-est-le-niveau-dhumidite-acceptable-avant-la-pose-dun-revetement-de-sol-en-caoutchouc\/","og_site_name":"MF FLOOR","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100079773047357","article_published_time":"2026-03-28T07:07:03+00:00","article_modified_time":"2026-04-09T07:12:32+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg","type":"image\/jpeg"}],"author":"1659230944@qq.com","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"1659230944@qq.com","Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#article","isPartOf":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/"},"author":{"name":"1659230944@qq.com","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef"},"headline":"What Moisture Level Is Acceptable Before Installing Rubber Flooring","datePublished":"2026-03-28T07:07:03+00:00","dateModified":"2026-04-09T07:12:32+00:00","mainEntityOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/"},"wordCount":1047,"commentCount":0,"publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg","articleSection":["Soundproof Flooring Solutions"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/","url":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/","name":"What Moisture Level Is Acceptable Before Installing Rubber Flooring - MF FLOOR","isPartOf":{"@id":"https:\/\/meettfit.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg","datePublished":"2026-03-28T07:07:03+00:00","dateModified":"2026-04-09T07:12:32+00:00","description":"Learn the acceptable moisture level before installing rubber flooring. See RH, MVER, wood subfloor limits, and how to avoid adhesive failure.","breadcrumb":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#primaryimage","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/Rubber-Flooring-4-4.jpeg","width":800,"height":600,"caption":"Rubber Flooring (4)"},{"@type":"BreadcrumbList","@id":"https:\/\/meettfit.com\/acoustic-underlay\/what-moisture-level-is-acceptable-before-installing-rubber-flooring\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/meettfit.com\/"},{"@type":"ListItem","position":2,"name":"What Moisture Level Is Acceptable Before Installing Rubber Flooring"}]},{"@type":"WebSite","@id":"https:\/\/meettfit.com\/#website","url":"https:\/\/meettfit.com\/","name":"MF FLOOR","description":"fitness and sports floor China factory","publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"alternateName":"MF FLOOR","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/meettfit.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/meettfit.com\/#organization","name":"MF FLOOR","alternateName":"MF FLOOR","url":"https:\/\/meettfit.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","width":512,"height":512,"caption":"MF FLOOR"},"image":{"@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100079773047357"]},{"@type":"Person","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef","name":"1659230944@qq.com","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","caption":"1659230944@qq.com"},"url":"https:\/\/meettfit.com\/fr\/author\/1659230944qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts\/7991","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/comments?post=7991"}],"version-history":[{"count":0,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts\/7991\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/media\/7996"}],"wp:attachment":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/media?parent=7991"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/categories?post=7991"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/tags?post=7991"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}