{"id":7939,"date":"2026-03-24T15:16:59","date_gmt":"2026-03-24T07:16:59","guid":{"rendered":"https:\/\/meettfit.com\/?p=7939"},"modified":"2026-04-08T17:55:51","modified_gmt":"2026-04-08T09:55:51","slug":"how-do-you-measure-gym-floor-impact-noise-iic","status":"publish","type":"post","link":"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/comment-mesurer-le-bruit-dimpact-du-sol-dun-gymnase\/","title":{"rendered":"Comment mesurer le bruit d'impact du sol d'un gymnase (IIC) ?"},"content":{"rendered":"<p>La mesure du bruit d'impact du sol d'un gymnase (IIC) n\u00e9cessite un test acoustique contr\u00f4l\u00e9 conforme aux normes ASTM E492 (en laboratoire) ou ASTM E1007 (sur le terrain). Le processus utilise une machine \u00e0 frapper normalis\u00e9e pour g\u00e9n\u00e9rer des bruits d'impact dans une \"salle source\", tandis que des microphones de haute pr\u00e9cision mesurent les niveaux de pression acoustique dans la \"salle r\u00e9ceptrice\" situ\u00e9e en dessous, afin de calculer une cote \u00e0 un seul chiffre.<\/p>\n<p>Pour mesurer avec pr\u00e9cision la classe d'isolation contre les chocs (IIC) d'un sol de gymnase, il faut suivre un protocole technique rigoureux. En tant qu'ing\u00e9nieur charg\u00e9 du contr\u00f4le de la qualit\u00e9, je me concentre sur la v\u00e9rification technique de la performance des mat\u00e9riaux. Il s'agit d'un calcul pond\u00e9r\u00e9 sur un spectre de fr\u00e9quences sp\u00e9cifique ($100\\text{ Hz}$ \u00e0 $3150\\text{ Hz}$). Bien que l'IIC soit la norme industrielle pour la conformit\u00e9 au code du b\u00e2timent (qui exige g\u00e9n\u00e9ralement l'IIC 50), il est important de noter que l'\u00e9quipement de test standard - la machine \u00e0 frapper - simule des impacts \u00e0 haute fr\u00e9quence tels que des bruits de pas ou la chute d'une cl\u00e9. Il ne rend pas pleinement compte de l'\u00e9nergie \u00e0 basse fr\u00e9quence d'un soul\u00e8vement de poids lourd ou d'une chute d'halt\u00e8re de 50 kg, qui n\u00e9cessite souvent des essais suppl\u00e9mentaires de chocs violents.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-3-9.jpg&quot;\" alt=\"installation professionnelle de mesure acoustique\" \/><\/p>\n<p>Les sections suivantes d\u00e9crivent en d\u00e9tail le mode op\u00e9ratoire technique exact pour effectuer une mesure standardis\u00e9e de l'IIC et interpr\u00e9ter les donn\u00e9es qui en r\u00e9sultent.<\/p>\n<h2>Quelle est la proc\u00e9dure normalis\u00e9e pour mesurer l'IIC de champ (AIIC) ?<\/h2>\n<p>The standard operating procedure for measuring impact noise in a gym involves calibrating class 1 sound level meters, generating consistent impact energy with a tapping machine, and correcting for background noise and room absorption. This process ensures the data reflects the floor&#8217;s performance rather than the room&#8217;s acoustics.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">\u00c9tape<\/th>\n<th style=\"text-align: left;\">Action<\/th>\n<th style=\"text-align: left;\">Exigences techniques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>1. Etalonnage<\/strong><\/td>\n<td style=\"text-align: left;\">\u00c9talonnage sur le terrain avant l'essai<\/td>\n<td style=\"text-align: left;\">Calibrateur acoustique (classe 1)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>2. Contexte<\/strong><\/td>\n<td style=\"text-align: left;\">Mesure $L_b$ dans la salle de r\u00e9ception<\/td>\n<td style=\"text-align: left;\">Doit \u00eatre $\\geq 10\\text{ dB}$ en dessous du signal<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>3. Excitation<\/strong><\/td>\n<td style=\"text-align: left;\">Utiliser une machine \u00e0 tarauder<\/td>\n<td style=\"text-align: left;\">5 marteaux, 10 impacts par seconde<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>4. L'absorption<\/strong><\/td>\n<td style=\"text-align: left;\">Mesure du temps de r\u00e9verb\u00e9ration ($T_{60}$)<\/td>\n<td style=\"text-align: left;\">Pour normaliser les effets d'\u00e9cho de la pi\u00e8ce<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Pour commencer la mesure, la machine \u00e0 frapper est plac\u00e9e \u00e0 au moins quatre endroits diff\u00e9rents sur le sol du gymnase pour tenir compte des variations structurelles. Dans la salle de r\u00e9ception situ\u00e9e en dessous, des microphones sont plac\u00e9s \u00e0 au moins cinq endroits ou d\u00e9plac\u00e9s sur une perche rotative afin de capturer une moyenne spatiale du niveau de pression acoustique ($L<em>n$). Si le bruit de fond est trop proche du signal d'essai, un facteur de correction doit \u00eatre appliqu\u00e9. En outre, \u00e9tant donn\u00e9 qu'une pi\u00e8ce \"vivante\" avec de nombreuses surfaces dures sonnera plus fort qu'une pi\u00e8ce meubl\u00e9e, nous devons mesurer le temps de r\u00e9verb\u00e9ration ($T).<\/em>{60}$) et normaliser les donn\u00e9es \u00e0 une surface d'absorption de r\u00e9f\u00e9rence de $10\\text{ m}^2$. Cela permet de s'assurer que l'indice IIC est une propri\u00e9t\u00e9 de l'ensemble du plancher, et non du mobilier de la pi\u00e8ce situ\u00e9e en dessous.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-5-8.jpg&quot;\" alt=\"machine \u00e0 tarauder sur sol en caoutchouc\" \/><\/p>\n<p>Une fois que les niveaux sonores bruts ont \u00e9t\u00e9 recueillis dans toutes les bandes de fr\u00e9quences, l'\u00e9valuation finale en un seul chiffre doit \u00eatre obtenue par un processus sp\u00e9cifique d'ajustement des courbes.<\/p>\n<h2>Comment la valeur finale de l'IIC est-elle calcul\u00e9e \u00e0 partir des donn\u00e9es de fr\u00e9quence ?<\/h2>\n<p>La valeur IIC est calcul\u00e9e en reportant les niveaux de pression acoustique mesur\u00e9s dans seize bandes de $1\/3$-octave sur le contour de r\u00e9f\u00e9rence de la norme ASTM E989. Le contour est d\u00e9cal\u00e9 verticalement jusqu'\u00e0 ce que la somme des \"insuffisances\" (points o\u00f9 le bruit d\u00e9passe le contour) soit inf\u00e9rieure ou \u00e9gale \u00e0 $32\\text{ dB}$, et qu'aucun pic ne d\u00e9passe $8\\text{ dB}$.<\/p>\n<h3>La logique de calcul<\/h3>\n<ul>\n<li><strong>Entr\u00e9e des donn\u00e9es<\/strong>: Niveaux de pression acoustique normalis\u00e9s ($L_n$) pour les bandes allant de $100\\text{ Hz}$ \u00e0 $3150\\text{ Hz}$.<\/li>\n<li><strong>Ajustement des contours<\/strong>: La courbe de r\u00e9f\u00e9rence est ajust\u00e9e par incr\u00e9ments de $1\\text{ dB}$.<\/li>\n<li><strong>Relation inverse<\/strong>: En IIC, un chiffre plus \u00e9lev\u00e9 est meilleur (il repr\u00e9sente plus de son bloqu\u00e9), contrairement aux d\u00e9cibels bruts o\u00f9 des chiffres plus \u00e9lev\u00e9s signifient plus de bruit.<\/li>\n<li><strong>La valeur unique<\/strong>: Le classement IIC est d\u00e9termin\u00e9 par la valeur du contour ajust\u00e9 \u00e0 $500\\text{ Hz}$.<\/li>\n<\/ul>\n<p>D'un point de vue technique, la r\u00e8gle du \"pic d'insuffisance\" est essentielle pour les sols des salles de sport. Si votre sol en caoutchouc a une fr\u00e9quence de r\u00e9sonance sp\u00e9cifique - ce qui est courant avec certaines miettes recycl\u00e9es de mauvaise qualit\u00e9 - vous pouvez observer un pic massif \u00e0 $125\\text{ Hz}$. M\u00eame si le reste du spectre est calme, ce seul pic \u00e0 $8\\text{ dB}$ \"tirera vers le bas\" l'ensemble de votre indice IIC. Cette m\u00e9thode de calcul oblige le syst\u00e8me de rev\u00eatement de sol \u00e0 fonctionner de mani\u00e8re coh\u00e9rente sur toutes les fr\u00e9quences, et pas seulement sur un ou deux points.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-1-9.jpg&quot;\" alt=\"Graphique de la courbe de calcul de l&#039;IIC\" \/><\/p>\n<p>Bien que cette mesure standard soit requise pour la conformit\u00e9 l\u00e9gale, il est souvent n\u00e9cessaire d'aller au-del\u00e0 de l'IIC pour prendre en compte la physique r\u00e9elle d'un gymnase \u00e0 usage intensif.<\/p>\n<h2>L'IIC mesure-t-il avec pr\u00e9cision le bruit produit par la chute d'un halt\u00e8re lourd ?<\/h2>\n<p>Les mesures IIC standard ne repr\u00e9sentent pas avec pr\u00e9cision les impacts lourds dans les salles de sport, car les marteaux des machines de frappe sont trop l\u00e9gers (0,5 kg chacun) pour exciter les vibrations \u00e0 basse fr\u00e9quence du sol caus\u00e9es par des poids lourds. Pour les environnements sp\u00e9cifiques aux salles de sport, un \"test d'impact lourd\" utilisant une balle en caoutchouc ou un sac de sable de 50 kg est souvent effectu\u00e9 en tant que compl\u00e9ment technique, en particulier lorsque la r\u00e9action du sol peut \u00e9galement influencer les r\u00e9sultats de l'entra\u00eenement, comme dans les cas suivants <a href=\"https:\/\/meettfit.com\/fr\/materiau-de-base\/limpact-des-materiaux-de-sol-hyrox-sur-la-combustion-des-calories-et-la-frequence-cardiaque\/\">br\u00fblage de calories et fr\u00e9quence cardiaque dans les s\u00e9ances d'entra\u00eenement de type Hyrox<\/a>.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Type de test<\/th>\n<th style=\"text-align: left;\">Poids de l'impacteur<\/th>\n<th style=\"text-align: left;\">Fr\u00e9quence Focus<\/th>\n<th style=\"text-align: left;\">Demande d'inscription au gymnase<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Standard IIC<\/strong><\/td>\n<td style=\"text-align: left;\">$0.5\\text{ kg}$ marteaux<\/td>\n<td style=\"text-align: left;\">Haut ($500\\text{ Hz}$+)<\/td>\n<td style=\"text-align: left;\">Bruits de pas, machines cardio<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Impact important<\/strong><\/td>\n<td style=\"text-align: left;\">$50\\text{ kg}$ impacteur<\/td>\n<td style=\"text-align: left;\">Low ($20\\text{ Hz}$ &#8211; $100\\text{ Hz}$)<\/td>\n<td style=\"text-align: left;\">Deadlifts, powerlifting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>En laboratoire, nous reconnaissons qu'un sol peut avoir un \"IIC \u00e9lev\u00e9\", mais qu'il reste \"bruyant\" lorsque quelqu'un laisse tomber un halt\u00e8re. Cela s'explique par le fait que l'\u00e9nergie de la machine de frappe reste principalement dans la gamme des fr\u00e9quences sup\u00e9rieures. Pour une \u00e9valuation technique compl\u00e8te d'une salle de sport, nous mesurons la \"r\u00e9ponse rapide maximale\" ($L_{max,F}$) dans la salle du dessous lors d'une chute importante. Cette mesure fournit un pic de d\u00e9cibels brut qui refl\u00e8te l'\u00e9nergie r\u00e9elle transf\u00e9r\u00e9e lors d'un \u00e9v\u00e9nement \u00e0 fort impact. Si vous devez r\u00e9soudre des probl\u00e8mes de voisinage dans un \u00e9tablissement professionnel, vous devez insister pour obtenir \u00e0 la fois un IIC standard pour les dossiers juridiques et une \u00e9valuation de l'impact lourd pour la performance fonctionnelle.<\/p>\n<p>Avant de faire appel \u00e0 un consultant ou de proc\u00e9der \u00e0 une mesure, il est essentiel de faire la distinction entre une \u00e9valuation faite soi-m\u00eame et un rapport de laboratoire certifi\u00e9.<\/p>\n<h2>Puis-je mesurer moi-m\u00eame l'IIC du sol d'un gymnase pour une \u00e9valuation pr\u00e9liminaire ?<\/h2>\n<p>Vous pouvez effectuer une \u00e9valuation pr\u00e9liminaire en utilisant une application de d\u00e9cibels de haute qualit\u00e9 pour smartphone afin de v\u00e9rifier les \"points faibles\" \u00e9vidents, mais vous ne pouvez pas produire une \u00e9valuation IIC certifi\u00e9e sans un \u00e9quipement professionnel. Un rapport certifi\u00e9 n\u00e9cessite des microphones de classe 1 et une cha\u00eene d'\u00e9talonnage document\u00e9e pour \u00eatre l\u00e9galement ou contractuellement valide.<\/p>\n<h3>Mesures bricol\u00e9es ou professionnelles<\/h3>\n<ul>\n<li><strong>Valeur du bricolage<\/strong>: Utile pour d\u00e9terminer si le bruit s'\u00e9chappe d'un mur sp\u00e9cifique (flanc) ou d'une porte. Il vous aide \u00e0 d\u00e9cider si le co\u00fbt d'un test professionnel en vaut la peine.<\/li>\n<li><strong>Quand faire appel \u00e0 un professionnel<\/strong>: Vous devez faire appel \u00e0 un membre du NCAC (National Council of Acoustical Consultants) si vous devez prouver la conformit\u00e9 au code de la construction (IBC 1206) ou si vous \u00eates impliqu\u00e9 dans un litige avec un voisin.<\/li>\n<li><strong>Le rapport<\/strong>: A professional report will include the floor&#8217;s cross-section, the $T_{60}$ correction data, and the IIC\/AIIC single-number rating.<\/li>\n<\/ul>\n<p>Dans les projets r\u00e9els, l'\u00e9cart entre les donn\u00e9es de laboratoire et les performances sur le terrain peut \u00e9galement \u00eatre influenc\u00e9 par des facteurs logistiques, notamment le fait de savoir si <a href=\"https:\/\/meettfit.com\/fr\/blog-sur-les-sols-en-caoutchouc\/lemballage-et-le-chargement-ont-ils-un-impact-sur-la-qualite-des-revetements-de-sol-en-caoutchouc\/\">emballage et chargement impact qualit\u00e9 des rev\u00eatements de sol en caoutchouc<\/a> avant que le mat\u00e9riel n'atteigne le site. Sur le terrain, vous perdrez probablement 5 \u00e0 8 points \u00e0 cause des flancs. Si votre rapport de laboratoire indique IIC 55, vous devez vous attendre \u00e0 un AIIC de 47 \u00e0 50 sur le site. Si vous avez besoin d'une mesure officielle pour l'obtention d'un permis de construction d'un gymnase commercial, le test sur le terrain est le seul qui compte.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-4-8.jpg&quot;\" alt=\"mesure du son par un professionnel ou un amateur\" \/><\/p>\n<h2>Conclusion<\/h2>\n<p>La mesure de l'IIC n\u00e9cessite un \u00e9quipement normalis\u00e9 et un calcul pond\u00e9r\u00e9 entre $100\\text{ Hz}$ et $3150\\text{ Hz}$ pour r\u00e9pondre aux normes de l'ASTM.<\/p>","protected":false},"excerpt":{"rendered":"<p>Measuring gym floor impact noise (IIC) requires a controlled acoustic test following ASTM E492 (laboratory) or ASTM E1007 (field) standards. The process uses a standardized tapping machine to generate impact sound in a &quot;source room,&quot; while high-precision microphones measure the sound pressure levels in the &quot;receiver room&quot; below to calculate a single-number rating. To accurately&#8230;<\/p>","protected":false},"author":4,"featured_media":7942,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[25],"tags":[],"class_list":["post-7939","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-acoustic-underlay"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How do you measure gym floor impact noise (IIC) - MF FLOOR<\/title>\n<meta name=\"description\" content=\"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/comment-mesurer-le-bruit-dimpact-du-sol-dun-gymnase\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How do you measure gym floor impact noise (IIC) - MF FLOOR\" \/>\n<meta property=\"og:description\" content=\"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/comment-mesurer-le-bruit-dimpact-du-sol-dun-gymnase\/\" \/>\n<meta property=\"og:site_name\" content=\"MF FLOOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-24T07:16:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-08T09:55:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"1659230944@qq.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"1659230944@qq.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\"},\"author\":{\"name\":\"1659230944@qq.com\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\"},\"headline\":\"How do you measure gym floor impact noise (IIC)\",\"datePublished\":\"2026-03-24T07:16:59+00:00\",\"dateModified\":\"2026-04-08T09:55:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\"},\"wordCount\":1206,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"articleSection\":[\"Soundproof Flooring Solutions\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\",\"url\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\",\"name\":\"How do you measure gym floor impact noise (IIC) - MF FLOOR\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"datePublished\":\"2026-03-24T07:16:59+00:00\",\"dateModified\":\"2026-04-08T09:55:51+00:00\",\"description\":\"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.\",\"breadcrumb\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"width\":800,\"height\":600,\"caption\":\"Rubber Flooring (2)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/meettfit.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How do you measure gym floor impact noise (IIC)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/meettfit.com\/#website\",\"url\":\"https:\/\/meettfit.com\/\",\"name\":\"MF FLOOR\",\"description\":\"fitness and sports floor China factory\",\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"alternateName\":\"MF FLOOR\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/meettfit.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/meettfit.com\/#organization\",\"name\":\"MF FLOOR\",\"alternateName\":\"MF FLOOR\",\"url\":\"https:\/\/meettfit.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"width\":512,\"height\":512,\"caption\":\"MF FLOOR\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\",\"name\":\"1659230944@qq.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"caption\":\"1659230944@qq.com\"},\"url\":\"https:\/\/meettfit.com\/fr\/author\/1659230944qq-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How do you measure gym floor impact noise (IIC) - MF FLOOR","description":"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/comment-mesurer-le-bruit-dimpact-du-sol-dun-gymnase\/","og_locale":"fr_FR","og_type":"article","og_title":"How do you measure gym floor impact noise (IIC) - MF FLOOR","og_description":"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.","og_url":"https:\/\/meettfit.com\/fr\/sous-couche-acoustique\/comment-mesurer-le-bruit-dimpact-du-sol-dun-gymnase\/","og_site_name":"MF FLOOR","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100079773047357","article_published_time":"2026-03-24T07:16:59+00:00","article_modified_time":"2026-04-08T09:55:51+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","type":"image\/jpeg"}],"author":"1659230944@qq.com","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"1659230944@qq.com","Dur\u00e9e de lecture estim\u00e9e":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#article","isPartOf":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/"},"author":{"name":"1659230944@qq.com","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef"},"headline":"How do you measure gym floor impact noise (IIC)","datePublished":"2026-03-24T07:16:59+00:00","dateModified":"2026-04-08T09:55:51+00:00","mainEntityOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/"},"wordCount":1206,"commentCount":0,"publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","articleSection":["Soundproof Flooring Solutions"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/","url":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/","name":"How do you measure gym floor impact noise (IIC) - MF FLOOR","isPartOf":{"@id":"https:\/\/meettfit.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","datePublished":"2026-03-24T07:16:59+00:00","dateModified":"2026-04-08T09:55:51+00:00","description":"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.","breadcrumb":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","width":800,"height":600,"caption":"Rubber Flooring (2)"},{"@type":"BreadcrumbList","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/meettfit.com\/"},{"@type":"ListItem","position":2,"name":"How do you measure gym floor impact noise (IIC)"}]},{"@type":"WebSite","@id":"https:\/\/meettfit.com\/#website","url":"https:\/\/meettfit.com\/","name":"MF FLOOR","description":"fitness and sports floor China factory","publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"alternateName":"MF FLOOR","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/meettfit.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/meettfit.com\/#organization","name":"MF FLOOR","alternateName":"MF FLOOR","url":"https:\/\/meettfit.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","width":512,"height":512,"caption":"MF FLOOR"},"image":{"@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100079773047357"]},{"@type":"Person","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef","name":"1659230944@qq.com","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/meettfit.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","caption":"1659230944@qq.com"},"url":"https:\/\/meettfit.com\/fr\/author\/1659230944qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts\/7939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/comments?post=7939"}],"version-history":[{"count":0,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/posts\/7939\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/media\/7942"}],"wp:attachment":[{"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/media?parent=7939"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/categories?post=7939"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meettfit.com\/fr\/wp-json\/wp\/v2\/tags?post=7939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}