{"id":7939,"date":"2026-03-24T15:16:59","date_gmt":"2026-03-24T07:16:59","guid":{"rendered":"https:\/\/meettfit.com\/?p=7939"},"modified":"2026-04-08T17:55:51","modified_gmt":"2026-04-08T09:55:51","slug":"how-do-you-measure-gym-floor-impact-noise-iic","status":"publish","type":"post","link":"https:\/\/meettfit.com\/es\/base-acustica\/como-se-mide-el-ruido-de-impacto-en-el-suelo-de-un-gimnasio-iic\/","title":{"rendered":"\u00bfC\u00f3mo se mide el ruido de impacto en el suelo de un gimnasio (IIC)?"},"content":{"rendered":"<p>La medici\u00f3n del ruido de impacto en el suelo de los gimnasios (IIC) requiere un ensayo ac\u00fastico controlado seg\u00fan las normas ASTM E492 (laboratorio) o ASTM E1007 (campo). El proceso utiliza una m\u00e1quina de golpeteo normalizada para generar sonido de impacto en una \"sala fuente\", mientras que los micr\u00f3fonos de alta precisi\u00f3n miden los niveles de presi\u00f3n sonora en la \"sala receptora\" situada debajo para calcular una clasificaci\u00f3n de un solo n\u00famero.<\/p>\n<p>Para medir con precisi\u00f3n la Clase de Aislamiento contra Impactos (IIC) de un suelo de gimnasio, hay que seguir un r\u00edgido protocolo de ingenier\u00eda. Como ingeniero de control de calidad, me centro en la verificaci\u00f3n t\u00e9cnica del rendimiento del material. Esta medici\u00f3n no es una simple \"lectura de decibelios\" de una aplicaci\u00f3n de tel\u00e9fono; es un c\u00e1lculo ponderado a trav\u00e9s de un espectro de frecuencia espec\u00edfico ($100\\text{ Hz}$ a $3150\\text{ Hz}$). Aunque IIC es la norma del sector para el cumplimiento de los c\u00f3digos de construcci\u00f3n (que suelen exigir IIC 50), es importante tener en cuenta que el equipo de ensayo est\u00e1ndar, la m\u00e1quina de golpeteo, simula impactos de alta frecuencia, como pisadas o llaves que se caen. No capta totalmente la energ\u00eda de baja frecuencia de un levantamiento de peso muerto o de la ca\u00edda de una mancuerna de 50 kg, lo que a menudo requiere pruebas suplementarias de impactos fuertes.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-3-9.jpg&quot;\" alt=\"equipo profesional de medici\u00f3n ac\u00fastica\" \/><\/p>\n<p>En las siguientes secciones se detallan los PNT t\u00e9cnicos exactos para realizar una medici\u00f3n CII normalizada e interpretar los datos resultantes.<\/p>\n<h2>\u00bfCu\u00e1l es el procedimiento normalizado normalizado para medir la CII de campo (CIIA)?<\/h2>\n<p>The standard operating procedure for measuring impact noise in a gym involves calibrating class 1 sound level meters, generating consistent impact energy with a tapping machine, and correcting for background noise and room absorption. This process ensures the data reflects the floor&#8217;s performance rather than the room&#8217;s acoustics.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Paso<\/th>\n<th style=\"text-align: left;\">Acci\u00f3n<\/th>\n<th style=\"text-align: left;\">Requisitos t\u00e9cnicos<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>1. Calibraci\u00f3n<\/strong><\/td>\n<td style=\"text-align: left;\">Calibraci\u00f3n de campo previa a la prueba<\/td>\n<td style=\"text-align: left;\">Calibrador ac\u00fastico (Clase 1)<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>2. Antecedentes<\/strong><\/td>\n<td style=\"text-align: left;\">Medida $L_b$ en sala receptora<\/td>\n<td style=\"text-align: left;\">Debe estar $\\geq 10\\text{ dB}$ por debajo de la se\u00f1al<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>3. Excitaci\u00f3n<\/strong><\/td>\n<td style=\"text-align: left;\">Manejar la roscadora<\/td>\n<td style=\"text-align: left;\">5 martillos, 10 impactos por segundo<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>4. Absorci\u00f3n<\/strong><\/td>\n<td style=\"text-align: left;\">Medir el tiempo de reverberaci\u00f3n ($T_{60}$)<\/td>\n<td style=\"text-align: left;\">Para normalizar los efectos de \"eco\" de la sala<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Para comenzar la medici\u00f3n, la m\u00e1quina de impactos se coloca en al menos cuatro lugares diferentes del suelo del gimnasio para tener en cuenta las variaciones estructurales. En la sala receptora situada debajo, se colocan micr\u00f3fonos en al menos cinco posiciones o se mueven en un brazo giratorio para captar una media espacial del nivel de presi\u00f3n sonora ($L<em>n$). Si el ruido de fondo est\u00e1 demasiado cerca de la se\u00f1al de ensayo, hay que aplicar un factor de correcci\u00f3n. Adem\u00e1s, como una sala \"viva\" con muchas superficies duras sonar\u00e1 m\u00e1s fuerte que una amueblada, hay que medir el tiempo de reverberaci\u00f3n ($T<\/em>{60}$) y normalizar los datos a un \u00e1rea de absorci\u00f3n de referencia de $10\\text{ m}^2$. Esto garantiza que la clasificaci\u00f3n IIC es una propiedad del conjunto del suelo, no de los muebles de la habitaci\u00f3n de abajo.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-5-8.jpg&quot;\" alt=\"m\u00e1quina de impactos sobre suelo de caucho\" \/><\/p>\n<p>Una vez recogidos los niveles sonoros brutos en todas las bandas de frecuencia, la clasificaci\u00f3n final de un solo n\u00famero debe obtenerse mediante un proceso espec\u00edfico de ajuste de curvas.<\/p>\n<h2>\u00bfC\u00f3mo se calcula el valor IIC final a partir de los datos de frecuencia?<\/h2>\n<p>El valor IIC se calcula trazando los niveles de presi\u00f3n ac\u00fastica medidos en diecis\u00e9is bandas de $1\/3$ octava frente al contorno de referencia ASTM E989. El contorno se desplaza verticalmente hasta que la suma de las \"deficiencias\" (puntos en los que el ruido supera el contorno) es inferior o igual a $32\\text{ dB}$, y ning\u00fan pico supera $8\\text{ dB}$.<\/p>\n<h3>La l\u00f3gica del c\u00e1lculo<\/h3>\n<ul>\n<li><strong>Entrada de datos<\/strong>: Niveles de presi\u00f3n sonora normalizados ($L_n$) para bandas de $100\\text{ Hz}$ a $3150\\text{ Hz}$.<\/li>\n<li><strong>Ajuste del contorno<\/strong>: La curva de referencia se ajusta en incrementos de $1\\text{ dB}$.<\/li>\n<li><strong>Relaci\u00f3n inversa<\/strong>: En IIC, un n\u00famero m\u00e1s alto es mejor (representa m\u00e1s sonido bloqueado), a diferencia de los decibelios brutos, donde n\u00fameros m\u00e1s altos significan m\u00e1s ruido.<\/li>\n<li><strong>El valor \u00fanico<\/strong>: La clasificaci\u00f3n IIC viene determinada por el valor del contorno ajustado a $500\\text{ Hz}$.<\/li>\n<\/ul>\n<p>Desde un punto de vista t\u00e9cnico, la regla del \"pico de deficiencia\" es fundamental para los suelos de los gimnasios. Si su suelo de caucho tiene una frecuencia de resonancia espec\u00edfica -com\u00fan con algunas migas recicladas de baja calidad-, es posible que vea un pico masivo a $125\\text{ Hz}$. Aunque el resto del espectro sea silencioso, ese \u00fanico pico de $8\\text{ dB}$ \"bajar\u00e1\" toda su clasificaci\u00f3n IIC. Este m\u00e9todo de c\u00e1lculo obliga al sistema de suelo a funcionar de forma coherente en todas las frecuencias, no s\u00f3lo en uno o dos puntos.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-1-9.jpg&quot;\" alt=\"Gr\u00e1fico de la curva de c\u00e1lculo IIC\" \/><\/p>\n<p>Aunque esta medici\u00f3n est\u00e1ndar es necesaria para el cumplimiento legal, a menudo es necesario ir m\u00e1s all\u00e1 de la CII para abordar la f\u00edsica real de un gimnasio de uso intensivo.<\/p>\n<h2>\u00bfMide la CII con precisi\u00f3n el ruido de una pesada ca\u00edda de mancuernas?<\/h2>\n<p>La medici\u00f3n CII est\u00e1ndar no representa con precisi\u00f3n los impactos fuertes en gimnasios porque los martillos de las m\u00e1quinas de golpeo son demasiado ligeros (0,5 kg cada uno) para excitar las vibraciones de baja frecuencia del suelo causadas por pesos pesados. Para entornos espec\u00edficos de gimnasio, a menudo se realiza una \"Prueba de impacto pesado\" utilizando una pelota de goma o un saco de arena de 50 kg como complemento t\u00e9cnico, especialmente cuando la respuesta del suelo tambi\u00e9n puede influir en el rendimiento del entrenamiento, como por ejemplo <a href=\"https:\/\/meettfit.com\/es\/material-de-base\/como-influyen-los-materiales-del-suelo-hyrox-en-la-quema-de-calorias-y-la-frecuencia-cardiaca\/\">quema de calor\u00edas y frecuencia cardiaca en entrenamientos estilo Hyrox<\/a>.<\/p>\n<table>\n<thead>\n<tr>\n<th style=\"text-align: left;\">Tipo de prueba<\/th>\n<th style=\"text-align: left;\">Peso del impactador<\/th>\n<th style=\"text-align: left;\">Frecuencia<\/th>\n<th style=\"text-align: left;\">Gimnasio Solicitud<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"text-align: left;\"><strong>Norma IIC<\/strong><\/td>\n<td style=\"text-align: left;\">$0.5\\text{ kg}$ martillos<\/td>\n<td style=\"text-align: left;\">Alto ($500\\text{ Hz}$+)<\/td>\n<td style=\"text-align: left;\">Pasos, m\u00e1quinas de cardio<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left;\"><strong>Fuerte impacto<\/strong><\/td>\n<td style=\"text-align: left;\">$50\\text{ kg}$ impactador<\/td>\n<td style=\"text-align: left;\">Low ($20\\text{ Hz}$ &#8211; $100\\text{ Hz}$)<\/td>\n<td style=\"text-align: left;\">Peso muerto, powerlifting<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>En el laboratorio, reconocemos que un suelo puede tener un \"IIC alto\" pero seguir sintiendo \"ruido sordo\" cuando alguien deja caer una pesa. Esto se debe a que la energ\u00eda de la m\u00e1quina de golpeo se mantiene principalmente en la gama de frecuencias superiores. Para una evaluaci\u00f3n t\u00e9cnica completa de un gimnasio, medimos la \"Respuesta R\u00e1pida M\u00e1xima\" ($L_{max,F}$) en la sala de abajo durante una ca\u00edda fuerte. Esto proporciona un pico de decibelios en bruto que refleja la energ\u00eda real transferida durante un evento de alto impacto. Si est\u00e1 resolviendo quejas de vecinos en una instalaci\u00f3n profesional, debe insistir tanto en una CII est\u00e1ndar para los registros legales como en una evaluaci\u00f3n de impactos fuertes para el rendimiento funcional.<\/p>\n<p>Antes de contratar a un consultor o intentar una medici\u00f3n, es fundamental distinguir entre una evaluaci\u00f3n realizada por uno mismo y un informe de laboratorio certificado.<\/p>\n<h2>\u00bfPuedo medir yo mismo la CII del suelo de un gimnasio para realizar una evaluaci\u00f3n preliminar?<\/h2>\n<p>Puedes realizar una evaluaci\u00f3n preliminar por ti mismo utilizando una aplicaci\u00f3n de decibelios de alta calidad para smartphone para comprobar si hay \"puntos d\u00e9biles\" evidentes, pero no puedes elaborar una clasificaci\u00f3n CII certificada sin un equipo profesional. Un informe certificado requiere micr\u00f3fonos de clase 1 y una cadena de calibraci\u00f3n documentada para tener validez legal o contractual.<\/p>\n<h3>Bricolaje frente a medici\u00f3n profesional<\/h3>\n<ul>\n<li><strong>Valor del bricolaje<\/strong>: \u00datil para identificar si el ruido se filtra a trav\u00e9s de una pared espec\u00edfica (flanqueo) o a trav\u00e9s de una puerta. Te ayuda a decidir si merece la pena pagar una prueba profesional.<\/li>\n<li><strong>Cu\u00e1ndo contratar a un profesional<\/strong>: Debe contratar a un miembro del NCAC (Consejo Nacional de Consultores Ac\u00fasticos) si necesita demostrar el cumplimiento del c\u00f3digo de edificaci\u00f3n (IBC 1206) o si est\u00e1 involucrado en una disputa legal con un vecino.<\/li>\n<li><strong>El informe<\/strong>: A professional report will include the floor&#8217;s cross-section, the $T_{60}$ correction data, and the IIC\/AIIC single-number rating.<\/li>\n<\/ul>\n<p>En los proyectos reales, esa diferencia entre los datos de laboratorio y el rendimiento sobre el terreno tambi\u00e9n puede verse afectada por factores log\u00edsticos, como si <a href=\"https:\/\/meettfit.com\/es\/suelo-de-goma-blog\/influyen-el-embalaje-y-la-carga-en-la-calidad-de-los-suelos-de-caucho\/\">embalaje y carga impacto suelo de caucho calidad<\/a> antes de que el material llegue al lugar. Sobre el terreno, es probable que pierda entre 5 y 8 puntos debido al flanqueo. Si su informe de laboratorio dice IIC 55, debe esperar un AIIC de 47 a 50 in situ. Si necesita una medici\u00f3n oficial para un permiso de gimnasio comercial, la prueba sobre el terreno es la \u00fanica que cuenta.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-4-8.jpg&quot;\" alt=\"medici\u00f3n del sonido profesional frente a la amateur\" \/><\/p>\n<h2>Conclusi\u00f3n<\/h2>\n<p>La medici\u00f3n de IIC requiere un equipo normalizado y un c\u00e1lculo ponderado a trav\u00e9s de $100\\text{ Hz}$ a $3150\\text{ Hz}$ para cumplir las normas ASTM.<\/p>","protected":false},"excerpt":{"rendered":"<p>Measuring gym floor impact noise (IIC) requires a controlled acoustic test following ASTM E492 (laboratory) or ASTM E1007 (field) standards. The process uses a standardized tapping machine to generate impact sound in a &quot;source room,&quot; while high-precision microphones measure the sound pressure levels in the &quot;receiver room&quot; below to calculate a single-number rating. To accurately&#8230;<\/p>","protected":false},"author":4,"featured_media":7942,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[25],"tags":[],"class_list":["post-7939","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-acoustic-underlay"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>How do you measure gym floor impact noise (IIC) - MF FLOOR<\/title>\n<meta name=\"description\" content=\"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/meettfit.com\/es\/base-acustica\/como-se-mide-el-ruido-de-impacto-en-el-suelo-de-un-gimnasio-iic\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How do you measure gym floor impact noise (IIC) - MF FLOOR\" \/>\n<meta property=\"og:description\" content=\"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/meettfit.com\/es\/base-acustica\/como-se-mide-el-ruido-de-impacto-en-el-suelo-de-un-gimnasio-iic\/\" \/>\n<meta property=\"og:site_name\" content=\"MF FLOOR\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\" \/>\n<meta property=\"article:published_time\" content=\"2026-03-24T07:16:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-08T09:55:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"1659230944@qq.com\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"1659230944@qq.com\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\"},\"author\":{\"name\":\"1659230944@qq.com\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\"},\"headline\":\"How do you measure gym floor impact noise (IIC)\",\"datePublished\":\"2026-03-24T07:16:59+00:00\",\"dateModified\":\"2026-04-08T09:55:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\"},\"wordCount\":1206,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"articleSection\":[\"Soundproof Flooring Solutions\"],\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\",\"url\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\",\"name\":\"How do you measure gym floor impact noise (IIC) - MF FLOOR\",\"isPartOf\":{\"@id\":\"https:\/\/meettfit.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"datePublished\":\"2026-03-24T07:16:59+00:00\",\"dateModified\":\"2026-04-08T09:55:51+00:00\",\"description\":\"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.\",\"breadcrumb\":{\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg\",\"width\":800,\"height\":600,\"caption\":\"Rubber Flooring (2)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/meettfit.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How do you measure gym floor impact noise (IIC)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/meettfit.com\/#website\",\"url\":\"https:\/\/meettfit.com\/\",\"name\":\"MF FLOOR\",\"description\":\"fitness and sports floor China factory\",\"publisher\":{\"@id\":\"https:\/\/meettfit.com\/#organization\"},\"alternateName\":\"MF FLOOR\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/meettfit.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/meettfit.com\/#organization\",\"name\":\"MF FLOOR\",\"alternateName\":\"MF FLOOR\",\"url\":\"https:\/\/meettfit.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"contentUrl\":\"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png\",\"width\":512,\"height\":512,\"caption\":\"MF FLOOR\"},\"image\":{\"@id\":\"https:\/\/meettfit.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/profile.php?id=100079773047357\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef\",\"name\":\"1659230944@qq.com\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/meettfit.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g\",\"caption\":\"1659230944@qq.com\"},\"url\":\"https:\/\/meettfit.com\/es\/author\/1659230944qq-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How do you measure gym floor impact noise (IIC) - MF FLOOR","description":"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/meettfit.com\/es\/base-acustica\/como-se-mide-el-ruido-de-impacto-en-el-suelo-de-un-gimnasio-iic\/","og_locale":"es_ES","og_type":"article","og_title":"How do you measure gym floor impact noise (IIC) - MF FLOOR","og_description":"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.","og_url":"https:\/\/meettfit.com\/es\/base-acustica\/como-se-mide-el-ruido-de-impacto-en-el-suelo-de-un-gimnasio-iic\/","og_site_name":"MF FLOOR","article_publisher":"https:\/\/www.facebook.com\/profile.php?id=100079773047357","article_published_time":"2026-03-24T07:16:59+00:00","article_modified_time":"2026-04-08T09:55:51+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","type":"image\/jpeg"}],"author":"1659230944@qq.com","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"1659230944@qq.com","Tiempo de lectura":"6 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#article","isPartOf":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/"},"author":{"name":"1659230944@qq.com","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef"},"headline":"How do you measure gym floor impact noise (IIC)","datePublished":"2026-03-24T07:16:59+00:00","dateModified":"2026-04-08T09:55:51+00:00","mainEntityOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/"},"wordCount":1206,"commentCount":0,"publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","articleSection":["Soundproof Flooring Solutions"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/","url":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/","name":"How do you measure gym floor impact noise (IIC) - MF FLOOR","isPartOf":{"@id":"https:\/\/meettfit.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage"},"image":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage"},"thumbnailUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","datePublished":"2026-03-24T07:16:59+00:00","dateModified":"2026-04-08T09:55:51+00:00","description":"Understand gym floor IIC testing, from tapping machine placement to ASTM curve fitting, plus why extra heavy-impact tests matter in gyms.","breadcrumb":{"@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#primaryimage","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2026\/03\/rubber-flooring-2-9.jpg","width":800,"height":600,"caption":"Rubber Flooring (2)"},{"@type":"BreadcrumbList","@id":"https:\/\/meettfit.com\/acoustic-underlay\/how-do-you-measure-gym-floor-impact-noise-iic\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/meettfit.com\/"},{"@type":"ListItem","position":2,"name":"How do you measure gym floor impact noise (IIC)"}]},{"@type":"WebSite","@id":"https:\/\/meettfit.com\/#website","url":"https:\/\/meettfit.com\/","name":"MF FLOOR","description":"fitness and sports floor China factory","publisher":{"@id":"https:\/\/meettfit.com\/#organization"},"alternateName":"MF FLOOR","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/meettfit.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/meettfit.com\/#organization","name":"MF FLOOR","alternateName":"MF FLOOR","url":"https:\/\/meettfit.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/","url":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","contentUrl":"https:\/\/meettfit.com\/wp-content\/uploads\/2025\/02\/cropped-icon.png","width":512,"height":512,"caption":"MF FLOOR"},"image":{"@id":"https:\/\/meettfit.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100079773047357"]},{"@type":"Person","@id":"https:\/\/meettfit.com\/#\/schema\/person\/ba93f0ead95f571b725acc83f6544fef","name":"1659230944@qq.com","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/meettfit.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a00f8b283a4395bb3fdf16b29335b3a4?s=96&d=mm&r=g","caption":"1659230944@qq.com"},"url":"https:\/\/meettfit.com\/es\/author\/1659230944qq-com\/"}]}},"_links":{"self":[{"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/posts\/7939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/comments?post=7939"}],"version-history":[{"count":0,"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/posts\/7939\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/media\/7942"}],"wp:attachment":[{"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/media?parent=7939"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/categories?post=7939"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/meettfit.com\/es\/wp-json\/wp\/v2\/tags?post=7939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}